C h a p t e r 9 P R O C E S S R E C I P E
7/26/00
INTEGRA Operations Revision A
9-43
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
.
Change IDLE HI FLOW DI
35 Toggle the IDLE HI FLOW DI
ON
or
OFF
(default:
OFF
) for Brush
Station #1 or Brush Station #2.
Once the system is in IDLE, and the idle time elapses (BRUSH
IDLE TIMER), the IDLE HI FLOW DI will turn ON to clean the
brushes. Brush cleaning continues for the interval time set in the
BRUSH IDLE ON TIME. Brush cleaning stops for the interval
time set in the BRUSH IDLE OFF TIME.
36
If the
IDLE CHEM,
and/or the
IDLE LOW FLOW DI
, and/or the
IDLE HI FLOW DI
are all set to
ON
, then they will all start at the
same time.
STANDARD