InTemp CX400 Series Temperature Logger Manual 

1-508-759-9500 (U.S. and International) 3 

www.onsetcomp.com 

1-800-LOGGERS (U.S. only) 

LCD Symbol 

Description 

 

This is an example of a minimum temperature, 
which is the lowest probe temperature reading 
from the day (CX402 models) or the lowest 
ambient temperature reading (CX403 model) 
within the current 24-hour period (midnight from 
one day to midnight the next day) if the logger 
was set to record logger checks (see 

Performing 

Logger Checks

). To clear this value, press the 

Mute/Next button for 3 seconds. If the logger 
check setting is not enabled, the minimum reading 
represents the entire logging period and only 
resets when the logger is downloaded and 
restarted or stopped and reconfigured, or if you 
press the Mute/Next button for 3 seconds (see 

Minimum and Maximum Values

). 

 

This is an example of a maximum temperature, 
which is the highest probe temperature reading 
from the day (CX402 models) or the lowest 
ambient temperature reading (CX403 model) 
within the current 24-hour period (midnight from 
one day to midnight the next day) if the logger 
was set to record logger checks (see 

Performing 

Logger Checks

). To clear this value, press the 

Mute/Next button for 3 seconds. If the logger 
check setting is not enabled, the maximum 
reading represents the entire logging period and 
only resets when the logger is downloaded and 
restarted or stopped and reconfigured, or if you 
press the Mute/Next button for 3 seconds (see 

Minimum and Maximum Values

). 

 

and 

 

The external probe is not connected to the logger 
(if applicable). 

 or  

 

MUTE indicates an alarm is beeping. Turn off the 
beeping alarm by pressing the Mute button. The 
LCD then changes to MUTED. 

 

The audible alarm has been muted. 

 

The logger has been configured to start logging on 
a delay. The display will count down in days, 
hours, minutes, and seconds until logging begins. 
In this example, 5 minutes and 38 seconds remain 
until logging will begin. 

 

The profile settings are being loaded onto the 
logger. 

 

An error occurred while loading the profile 
settings onto the logger. Try reconfiguring the 
logger. 

 

The logger was paged from the InTemp app. 

 

The logger has been downloaded and stopped 
with the InTemp app or because the memory is 
full. 

 

The logger is being updated with new firmware. 

Note: 

If the logger has stopped logging because the memory is 

full, the LCD screen will remain on with “STOP” displayed until 
the logger is downloaded to your mobile device. Once the 
logger has been downloaded, the LCD will turn off 
automatically after 2 hours. The LCD will turn back on the next 
time the logger connects with your device. 

Getting Started 

InTempConnect is web-based software where you can monitor 
CX400 series logger configurations and view downloaded data 

online. Using the InTemp app, you can configure the logger 
with your phone or tablet and then download reports, which 
are saved in the app and automatically uploaded to 
InTempConnect. The CX5000 Gateway is also available to 
automatically configure and download loggers and upload data 
to InTempConnect. Or anyone can download a logger using the 
InTempVerify app if the loggers are enabled to be used with 
InTempVerify. See www.intempconnect.com/help for details on 
both the gateway and InTempVerify. If you do not need to 
access logged data via the cloud based InTempConnect 
software, then you also have the option to use the logger with 
the InTemp app only 

Follow these steps to begin using the loggers with 
InTempConnect and the InTemp app. 

1.

 

Administrators:

 

Set up an InTempConnect account

. Follow 

all steps if you are a new administrator. If you already have 
an account and roles assigned, follow steps c and d.

 

If you are using the logger with the InTemp app only, skip 
to step 2. 

a.

 

Go to www.intempconnect.com and follow the prompts 
to set up an administrator account. You’ll receive an 
email to activate the account. 

b.

 

Log into www.intempconnect.com and add roles for the 
users you will be adding to the account. Click Settings and 
then Roles. Click Add Role, enter a description, select the 
privileges for the role and click Save. 

c.

 

Click Settings and then Users to add users to your 
account. Click Add User and enter the email address and 
first and last name of the user. Select the roles for the 
user and click Save. 

d.

 

New users will receive an email to activate their user 
accounts. 

2.

 

Set up the logger.

 Insert two AAA batteries in the logger, 

observing polarity. Insert the battery door in the back of the 
logger making sure it is flush with the rest of the logger 
case. Use the included screw and a Phillips-head 
screwdriver to screw the battery door into place.

 

Insert the external temperature probe (if applicable). 

3.

 

Download the InTemp app and log in. 

a.

 

Download InTemp to a phone or tablet from the App 
Store® or Google Play™. 

b.

 

Open the app and enable Bluetooth in the device settings 
if prompted. 

c.

 

InTempConnect users:

 Log in with your InTempConnect 

account email and password from the InTempConnect 
User screen. 

InTemp app only users:

 Swipe left to the Standalone User 

screen and tap Create Account. Fill in the fields to create 
an account and then log in from the Standalone User 
screen. 

4.

 

Configure the logger

.

 

InTempConnect users: 

Configuring the logger requires 

privileges. The logger includes preset profiles. 
Administrators or those with the required privileges can 
also set up custom profiles (including setting up daily logger 
checks) and trip information fields. This should be done 
before configuring the logger. If you plan to use the logger 

Summary of Contents for InTemp CX402-T205

Page 1: ...o 212 F Resolution 0 024 C at 25 C 0 04 F at 77 F Drift 0 1 C 0 18 F per year NIST Calibration CX40x Txx and CX402 BxM Single point NIST calibration probe and logger body CX40x VFCxxx Single point NIS...

Page 2: ...or measures ambient temperature External Temperature Probe This is the probe that is plugged into the logger for measuring temperature CX402 models only Audible Alarm Speaker This is the speaker for t...

Page 3: ...oftware where you can monitor CX400 series logger configurations and view downloaded data online Using the InTemp app you can configure the logger with your phone or tablet and then download reports w...

Page 4: ...nimum and maximum readings represent the entire logging period and only reset when the logger is downloaded and restarted or stopped and reconfigured they will not reset if you download the logger and...

Page 5: ...empConnect when you download the logger Log in to InTempConnect to build custom reports requires privileges In addition InTempConnect users can also download CX loggers automatically on a regular basi...

Page 6: ...h this reset Logger Events The logger records the following events to track logger operation and status These events are listed in reports downloaded from the logger Event Name Definition Started The...

Page 7: ...ts in extremely cold or hot temperatures or a logging interval faster than 1 minute can impact battery life Estimates are not guaranteed due to uncertainties in initial battery conditions and operatin...

Page 8: ...o radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh...