![onsen ONHW26LP50 Installation And Operating Manual Download Page 36](http://html1.mh-extra.com/html/onsen/onhw26lp50/onhw26lp50_installation-and-operating-manual_1638441036.webp)
Page
35
Version 1.0Aug 2018
6.
If there is more than one remote control installed, the following priority switching operations apply :
i.
Turn off hot water delivery at all outlets.
ii.
With power ON, in standby mode, and display OFF, press ON button of the remote control to assign
it priority status. The priority indicator will illuminate and the remote control can now adjust water
temperature. After priority has been assigned to a specific controller, the priority light on all other
controllers will dim and temperature adjustment from these controllers is not possible.
iii.
With powered ON, in standby mode, and display ON, press any button of any remote control to
assign it priority status. The priority indicator will illuminate and the remote control can now adjust
water temperature. After priority has been assigned to a specific controller, the priority light on all
other controllers will dim and temperature adjustment from these controllers is not possible.
iv.
When the water heater is in operation and delivering hot water, the priority cannot be reassigned
to other remote controls. Priority reassignment can only take place when there is no hot water
delivery.
v.
When the ON/OFF button of the remote control with priority is pressed, it will turn off the water
heater as well as all other remote controls. The controller will retain its priority with indicator on.
vi.
To determine the priority and address codes of multiple controllers, turn OFF all controllers and
press and hold
for 5seconds until buzzer sounds. The display will now show previous set
address code, or default address “11”. Press
button to set the address code of each remote
control to “12” or “13”. After setting the address code, press the power button
or wait for 3
seconds to automatically save any updated settings. This setting will be saved and remain in place
even when powered off. Press ON/OFF button again to exit setting.