Strata Enabled Smart LiB Gauge Automatic Support Tool
13
5.
Measurement Conditions Input Feature
In the Measurement Conditions Input Feature, you can select operational mode corresponding to the above hardware setup
methods. Select the conditions according to the procedures given in Table 3.
Figure 15. MEASUREMENT CONDITIONS INPUT FEATURE
Table 3. HARDWARE SETUP AND MEASUREMENT CONDITIONS
Hardware Setup
Battery Status
On-board Load
Current Slider
1. Discharge cell voltage curve measurement with on-board load
Discharge
Enable
On-Board Load Current
2. Discharge cell voltage curve measurement with an external load device
Discharge
Disable
External Load Current
3. Charge cell voltage curve measurement with an external charger
Charge
Disable
Charging Current
6.
Current Value Input Feature
In the Current value Input Feature, you can set discharging or charging current. There are three sliders available, but only one
(On-board Load Current) can be selected, as shown in Table 3. “Estd. Test Time” and “Log Interval” are displayed to the
right of the slider. “Estd. Test Time” is used to stop measurements that are too long automatically. “Log Interval” controls the
cell voltage measurement period. The platform control calculates these values automatically based on the users data. Input
current value related details is given in Table 4.
Figure 16. CURRENT INPUT FEATURE
Table 4. INPUT CURRENT FOR CURRENT SLIDER
Current Slider
Input Current
On-Board Load Current
On-board load current. The input range is from 4 mA to 1.5 A. This current controls on-board load circuits.
External Load Current
Discharging current for an external load device. The input range is from 1 mA to 6 A. If the current contains
fluctuation, input the approximate average current.
This current is used to calculate “Estd. Test Time” and
“Log Interval” on right.
Charging Current
Constant charging current of external charger in CC charging mode. The input range is from 1 mA to 6 A.
This current is used to calculate “Estd. Test Time” and “Log Interval”.