![ONNLINE Onnflood CEB976 User Manual Download Page 2](http://html1.mh-extra.com/html/onnline/onnflood-ceb976/onnflood-ceb976_user-manual_1638293002.webp)
2
Operation instruction
GB
Please read the use instructions carefully before use. And please keep this instruction for future reference.
1. Specification:
SAP code
CEB976
CEB978
CEB977
CEB979
Supply
Voltage
100~240V -
50Hz/60Hz
100~240V -
50Hz/60Hz
200~240V -
50Hz/60Hz
200~240V -
50Hz/60Hz
Power
Consumption
50W
80W
100W
200W
Lumen Output
5000lm
8000lm
10000lm
20000lm
Color
Temperature
4000K
4000K
4000K
4000K
CRI
>70
>70
>70
>70
Beam angle
140*70
140*70
140*70
140*70
Power Factor
>0.9
>0.9
>0.9
>0.9
Operating
Temp Range
-35
°
C <Ta < 50
°
C
-35
°
C <Ta < 50
°
C
-35
°
C <Ta < 50
°
C
-35
°
C <Ta < 50
°
C
IP Rating
65
65
65
65
IK Rating
08
08
08
08
Safety
Classification
Class I
Class I
Class I
Class I
Average Lamp
Life
50,000 Hours
50,000 Hours
50,000 Hours
50,000 Hours
Dimensions(
mm)
254*84*292
254*84*292
277*84*392
381*89*395
Weight
3.3kgs
3.5kgs
4.1kgs
6.0kgs
Installation
wall mounted
wall mounted
wall mounted
wall mounted
2. Safety instruction:
Electrical products can cause death or injury damage to property. If in any doubt about the installation or use of this
product, please consult a competent electrician.
1)
Before mounting and maintenance please make sure that the electrical supply has been switched off to avoid
electric shock.
2)
The light must be earthed.
3)
Replace the cracked protection glass immediately and use only original parts to substitute.
4)
Before maintenance work, the power should be switched off. The maintaining should be done only by a
qualified electrician.
3. Installation: