2.3 - LEDs
LED
On
Off
Blink
Pulse
HDD
-
-
Internal
storage drive
activity
-
Power
Device is on
Device is off
Device is
asleep
-
Automotive
Ignition
Ignition input to
device is on
Ignition input to
device is off
-
-
Watchdog
Internal MCU is
not functioning
normally
Internal MCU is
not functioning
normally
Firmware
bootloader
is active
Internal MCU is
functioning
normally
LEDs 1-4
Currently
selected
user mode
Currently selected
user mode
-
-
2.4 - Automotive Ignition Power Sensing (IGN)
The K300 3-pin power input terminal offers automotive ignition sensing. The ignition sensing timing
for power on and off delays can be modified through OnLogic’s microcontroller (MCU) using serial
commands. These commands allow setting the delay on startup after ignition is detected, the delay
until soft and hard shutdown when ignition is lost, and enabling/disabling ignition sensing. For more
information on ignition power sensing, and instructions on using these serial commands from
Karbon series technical support site
Pin
Definition
1
GND
2
Ignition
3
9~36 VDC Input
Summary of Contents for K300-E3930-4P-P