M-5000R
SERVICE PROCEDURE - 2
3. Adjustment of Meter
Please check the meter in the level state with the location of the look.
If checking the meter in the state which isn't level with the location of the look, it become with wrong judgement of
acceptance.
Indicator is out of 0 line in point and shift dimension for 0 line is less than 1mm. >> Part is OK.
A
OK : A < 1mm
[ Adjustment ]
1) A minus driver makes a hole in a tape
on the adjustment hole.
2) Adjust indicator to 0 line with
adjustment part(Move an adjustment
part to left and right and adjust).
3) Put TAPE on adjustment hole after
adjust.