![Onkyo HT-RC270B Service Manual Download Page 2](http://html1.mh-extra.com/html/onkyo/ht-rc270b/ht-rc270b_service-manual_1637469002.webp)
HT-RC270
SERVICE PROCEDURE-1
ON/STANDBY
C l e a r
Stand-by
VCR/DVR
1. Replacing the fuses
2. Safety check out
(U.S.A. model only)
After correcting the original service problem, perform the following safety check before releasing the unit to the customer.
Leakage current Check
Measure the leakage current to a known earth ground (water pipe or conduct etc.) by connecting a leakage current
tester between the earth ground and exposed metal parts of the unit (input/output ground terminals, screw heads or metal overlays etc.).
Plug the power supply cord directly into a 120Vac 60Hz wall socket and turn ON/STANDBY button on.
Any current measured must not exceed 0.5mA.
3. Memory Backup
This model uses a EE-PROM IC in order to retain radio presets and other settings. So, memory contents will be
kept eternally with no care.
4. To initialize the unit
1.
ON/STANDBY (
Power On)
2.
VCR/DVR
+
ON/STANDBY
.
Preset memory and each mode stored in the memory, are
initialized and will return to the factory settings.
This symbol located near the fuse indicates that the
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse, For fuse rating, refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
REF NO.
PART NAME
DESCRIPTION
PART NO.
REMARKS
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
F2000
F2000 or
F2001
F2001 or
F6901
F6901 or
F6902
F6902 or
F901
4A-UL/T-233
4A-T/UL-ST2
2A-UL/T-233
2A-T/UL-ST2
15A-TUL-250V
15A-UL/T-314
15A-TUL-250V
15A-UL/T-314
10A-UL-ST6 N1
252325GR
252257GR
252320GR
252253GR
252303GR
252197GR
252303GR
252197GR
252382GR
!
!
!
!
!
!
!
!
!