OPERATION CHECK-1
DC VOLTAGE DETECTION PROTECTORS
CURRENT DETECTION PROTECTORS
HT-R8230
1. Set the unit to test mode
" Test-1-00 "
.
1-1. Press and the hold down the
CD
button , then press the
STANDBY/ON
button when the unit is Power ON.
1-2. Press the
DVD
button, while the display of
" Test - _ "
has come out.
Unit will be in the state of "
Test-1-00
".
2. Apply DC voltage (+1.5 to +3V) to MULTI CHANNEL (FL, FR, SL, SR, C, SW) terminal, each channel.
3. Check that
" Protect "
is display come out.
4. Apply DC voltage (-1.5 to -3V) to MULTI CHANNEL (FL, FR, SL, SR, C, SW) terminal, each channel.
5. Check that
" Protect "
is display come out.
6. Press the
STANDBY/ON
button.
[NOTE1]
Limit time to apply voltage is 0.5 to 1.0 seconds each channel.
When protection operation does not occur at once, try several times.
[NOTE2]
Don't connect speakers or any load.
Don't short speaker terminals.
[NOTE]
In the state of test mode
" Test-4-29 "
, the pulse waveform output for checking from speaker terminal automatically.
Therefore, oscllator is unnecessary.
T e s t - _
T e s t - 1 - 0 0
C l e a r
Disappears
1. Set the unit to test mode
" Test-4-29 "
1-1. Press and the hold down the
CD
button , then press the
STANDBY/ON
button when the unit is Power ON.
1-2. Press the
VIDEO 3
button, while the display of
" Test - _ "
has come out.
Unit will be in the state of "
Test-4-00
".
1-3. Repeat and press
SPEAKERS B
button until the display of "
Test-4-29
" comes out.
2. Connect the lord resister (3 ohms) to the speaker terminals.
3. Check the not displayed
" Protect "
and speaker relays not turn OFF.
4. Check the each speaker terminals.
5. Connect the lord resister (1.5 ohms) to the speaker terminals.
6. Check the displayed
" Protect "
and speaker relays turn OFF immediately.
7. Check the each speaker terminals.
8. Press the
STANDBY/ON
button.
T e s t - _
T e s t - 4 - 0 0
T e s t - 4 - 2 9
C l e a r
Disappears