DV-SP1000
SERVICE PROCEDURES-2
Factory-shipped condition
Push button "ON" (Mechanical SW) Except
<DC1N>
Press the [
STOP
] and [
STANDBY
] same time.
(Wait until FL display "No Disc") .
Push button "
STANDBY
".
INITIALIZING
Others
SURR. MODE Switch -------- "1" position
Mechanical power switch ---- ON
2. Safety-check out
(Only U.S.A. model)
After correcting the original service problem perform the
following safety check before releasing the set to the customer
Connect the insulating-resistance tester between the plug of
power supply cord and terminal GND on the back panel.
Specifications: More than 10M ohm at 500V