![Onkyo DV-CP706 Service Manual Download Page 26](http://html.mh-extra.com/html/onkyo/dv-cp706/dv-cp706_service-manual_1636708026.webp)
DV-CP706
OPERATION GUIDE
Initialization
1. Press the "STOP" & "STANDBY" at the same with NO DISC condition.
2. Will display "COMPLETE" on FL tube after initializing for setting & mechanism.
The unit will be going to "STANDBY" after display "COMPLETE".
*All of the setting(VIDEO, AUDIO & etc.) will be initialized.
Please refer the "Default Setting" for each destination.
Region cord check
Test mode
1. Press the "STOP" & "DISPLAY" at the same with NO DISC condition.
Current version number of sub-micon is displayed on the FL tube.
2. Press the "DISPLAY".
Current version number of BACK END micon is displayed on the FL tube.
3 Press the "DISPLAY".
All segment of FL tube light up.
4. Press the "DISPLAY".
Will be displayed "DISPLAY KEY" on FL tube.
Press any keys except "STANDBY".
The function name of pressed key is display on the FL tube.
Press each key and confirm that the name of pressed key.
5. Press "STANDBY" to exit the test mode.
1. Press “STOP” button while press and holding “DISPLAY” button at NO DISC condition.
2. Press “DISPLAY” button twice. Displayed current version number of B/E micon on the FL tube.
Release Version : OE :******* (HPR2------)
FE Version : 10.26
BE Version : 1508530000
Please chech this code.
H : Writing of HDCP key.
P : Writing of CPPM key.
(Other model only)
R : Writing CPRM key.
(Other model only)
2 : Region number.
EX) MDD1N = 1, MPP2P = 2, MUA4P = 4,
MJJ2N = 2, MUT3P = 3, MUF3P = 3