DV-CP704
OPERATION GUIDE
Initialization
1. Press the "
STOP
" & "
STANDBY
" at the same with NO DISC condition.
2. Will display "
COMPLETE
" on FL tube after initializing for setting & mechanism.
The unit will be going to "
STANDBY
" after display "
COMPLETE
".
*All of the setting(VIDEO, AUDIO & etc.) will be initialized.
Please refer the "Default Setting" for each destination.
Destination setting
R1732
R1736
R1710
R1718
Destination
Region Code TV mode
CDD1N
OPEN
2.7Kohm
OPEN 10Kohm
North America
1
NTSC
CUA4P
2.7Kohm
OPEN
OPEN 10Kohm
Australia
4
PAL / AUTO
CDD1N
OPEN
2.7Kohm 2.7Kohm OPEN
North America
1
NTSC
DPC-7.7
Region cord check
Press Dimmer key and Pause key at the same time , after release press pause key again.
Display REGION CORD on FL.
CDD1N : USA 1 NTSC
CPA4P : AUS 4 PAL
Test mode
1. Press the "STOP" & "DISPLAY" at the same with NO DISC condition.
Current version number of sub-micon is displayed on the FL tube.
2. Press the "DISPLAY".
Current version number of BACK END micon is displayed on the FL tube.
3 Press the "DISPLAY".
All segment of FL tube light up.
4. Press the "DISPLAY".
Will be displayed "DISPLAY KEY" on FL tube.
Press any keys except "STANDBY".
The function name of pressed key is display on the FL tube.
Press each key and confirm that the name of pressed key.
5. Press "STANDBY" to exit the test mode.