HTP-120
SERVICE NOTE
1. Replacing the fuses
This symbol located near the fuses indicates that the fuse used is
fast operating type. For continued protection against fire hazard, re-
place with same type fuse. For fuse rating refer to the marking adja-
cent to the symbol.
Ce symbole indique que le fusible utlise est a rapide. Pour une pro-
tection permanente, n'untiliser que fusibles de meme type. Ce darni-
er est la qu le present symbol est appse.
CIRCUIT NO. PART NO. DESCRIPTION
F901 252159 or 2A-UL/T-237 or
252253 2A-T/UL-ST2
2. Safety-check out
After correcting the original service problem, perform the following
safety check before releasing the set to the customer. Connect the in-
sulating-resistance tester between the plug of power supply cord and
screw on the back panel.
Specifications: 3.3M ohm+/-10% at 500V.
Leakage
current
tester
Reading should
not be above
0.5mA
Device
under
test
Test all
exposed metal
surfaces
Earth
ground
AC Leakage Test