background image

A-9155

SCHEMATIC DIAGRAMS-3

A-9155

U08

POWER SWITCH 
PC BOARD

U10  

POWER SUPPLY PC BOARD

U11

TRANS. PRI. 
TERMINAL 
PC BOARD

AC-H

AC-G

AC CABLE

THERMAL

FUSE

POWER TRANSFORMER

P/D-TYPE

W-TYPE 220V

W-TYPE 120V

6

2

4

16

15

13

10

14

7

POWER

NASW-9254

NAPS-9257

T902

TO NAPS-9247

POFF

POWER

POFF

+9V

RLGND

RLGND

POWER

27.7mA

P/G TYPE : NPT-1519GQ

J/D TYPE : NPT-1519JQ

T901

T2.5AL250V

GND

NAPS-9256

T1.6AL250V

F901

TO NACPU-9251

4

6

P913B

P912B

P911B

2

7

P901B

P902B

S901

P901A

P902A

C916

223J

P911A

C904
104Z

R917

33K

R916

18K

R918

27K

D909

UDZS5.1B

C920

2.2/50

+

C918

104J

C919

104J

Q907

S-80127CN

4

OUT

3

NC

2

VSS

1

VSS

5

VDD

D906

RL1N4003

D904

RL1N4003

R909

22(1/2W)

R906

2.2(1/2W)

Q901

DTC123JKA

J931
NC

F903

P900A

2

1

D910

1SS352

D911

1SS352

C917

102J

T901

9

8

6

5

4

1

P912A

D901

1SS352

RL901

1

2

3

4

D908
S1NB60-4062

1

2

4

3

E901

1

3

4

2

C913A
NC

+

C913

3300/16

+

P910

1

2

4

3

P981

WS-CLAMP

JL901B

1

2

3

4

C902

NC

C911

103M/275V

<Note>

NC = No mount of parts.

SD-Z : XY

Location of connected terminal in schematic diagrams.
SD-Z = Schematic diagrams-Z. X = A to H, Y = 1 to 5.

AGAINST FIRE HAZARD, REPLACE

V

A

FOR CONTINUED PROTECTION

AND RATING INDICATED.

ONLY WITH FUSE OF SAME TYPE

CAUTION

ATTENTION

ET CALIBRATION COMME INDIQUE.

D'INCENDIE, REMPLACER UNIQUEMENT

PERMANENTE CONTRE LES RISQUES

AFIN D'ASSURER UNE PROTECTION

PAR UN FUSIBLE DE MEME TYPE

V

A

E LENT.POUR UNE PROTECTION PERMANENTE,N'UTILISER

INDIQUE LA QU LE PRESENT SYMBOL EST APPOSE.

QUE DES FUSIBLES DE MEME TYPE. CE DARNIER EST

CE SYMBOLE INDIQUE QUE LE FUSIBLE UTLISE EST

FOR CONTINUED PROTECTION AGAINST FIRE

RATING REFER TO THE MARKING ADJACENT TO THE SYMBOL.

HAZARD,REPLACE WITH SAME TYPE FUSE. FOR FUSE

THIS SYMBOL LOCATED NEAR THE FUSE INDICATES
THAT THE FUSE USED IS SLOW OPERATING TYPE

AC IN 230V, 50Hz

OUTLET

THE COMPONENTS IDENTIFIED BY MARK        ARE CRITICAL FOR SAFETY

REPLACE ONLY WITH PART NUMBER SPECIFIED.

VOLTAGE (MEASURED WITH VOLTMETER)                  IS DC VOLTAGE.(NO INPUT SIGNAL).

ALL PNP TRANSISTORS ARE EQUIVALENT TO 2SA1015-GR UNLESS OTHERWISE NOTED.

ALL NPN TRANSISTORS ARE EQUIVALENT TO 2SC1815-GR UNLESS OTHERWISE NOTED.

ALL DIODES ARE EQUIVALENT TO 1SS133 UNLESS OTHERWISE NOTED.

ELECTROLYTIC CAPACITORS (            ) ARE IN uF/WV.

ALL CAPACITORS ARE IN pF/50WV UNLESS OTHERWISE NOTED.

EX) 030- 3pF 330- 33pF 331- 330pF 333- 0.033uF

ALL RESISTORS ARE IN OHMS 1/4WATTS UNLESS OTHERWISE NOTED.

THE THICK LINES ON PC BOARD ARE THE PRINTING SIDE OF THE PARTS.

EX)                            PRINTING SIDE

CIRCUIT IS SUBJECT TO CHANGE FOR IMPROVEMENT.

!

NOTE

A

1

2

3

4

B

C

D

E

Summary of Contents for A-9155

Page 1: ... COMPONENTS IDENTIFIED BY MARK ON THE SCHEMATIC DIAGRAM AND IN THE PARTS LIST ARE CRITICAL FOR RISK OF FIRE AND ELECTRIC SHOCK REPLACE THESE COMPONENTS WITH ONKYO PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL MAKE LEAKAGE CURRENT OR RESISTANCE MEASUREMENTS TO DETERMINE THAT EXPOSED PARTS ARE ACCEPTABLY INSULATED FROM THE SUPPLY CIRCUIT BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER ...

Page 2: ...A121 A130 A136 A127 A124 A100 A202 P901 A010 A053 x 2 pcs A057 x 2 pcs A058 x 4 pcs A002 x 9 pcs A055 x 2 pcs A201 x 17 pcs A045 x 3 pcs A046 x 3 pcs A042 x 5 pcs A047 x 2 pcs A061 x 2 pcs Q521A x 4 pcs A148 x 2 pcs A501A x 8 pcs A147 x 2 pcs A044 x 3 pcs A028 x 4 pcs A031 x 4 pcs A029 x 4 pcs U03 T902 U11 U10 U04 U01 A025 F901 D901 Q521 Q524 Q522 Q523 F903 A041 A043 A062 A060 A051 A052 A037 A200 ...

Page 3: ...A121 A130 A136 A127 A124 A100 A202 P901 A010 A053 x 2 pcs A057 x 2 pcs A058 x 4 pcs A002 x 9 pcs A055 x 2 pcs A201 x 17 pcs A045 x 3 pcs A046 x 3 pcs A042 x 5 pcs A047 x 2 pcs A061 x 2 pcs Q521A x 4 pcs A148 x 2 pcs A501A x 8 pcs A147 x 2 pcs A044 x 3 pcs A028 x 4 pcs A031 x 4 pcs A029 x 4 pcs U03 T902 U11 U10 U04 U01 A025 F901 D901 Q521 Q524 Q522 Q523 F903 A041 A043 A062 A060 A051 A052 A037 A200 ...

Page 4: ...FLIN2 33 SRIN2 32 SLIN2 31 SWIN2 30 CIN2 29 SBRIN2 28 SBLIN2 27 TRE_R 26 BASS_R2 25 BASS_R1 24 AVCC 23 TRE_L 22 BASS_L2 21 BASS_L1 20 FRC 19 FROUT 18 AGND 17 FLOUT 16 FLC 15 6 C 14 6 OUT 13 AGND 12 5 OUT 11 5 C 10 4 C 9 4 OUT 8 AGND 7 3 OUT 6 3 C 5 2 C 4 2 OUT 3 AGND 2 1 OUT 1 1 C 80 SBRIN1 79 SBLIN1 78 SRIN1 77 SLIN1 76 SWIN1 75 CIN1 74 FRIN1 73 FLIN1 72 RECL3 71 RECR3 70 INL11 RECL5 69 INR11 REC...

Page 5: ... I C908A NC C910 10 50 J901NC C591 103J C538 NC C537 NC P431 WS CLAMP P432 WS CLAMP C438 220 16 C907 104J C914 NC C913 NC Q922B Q921B C920 1 50 Q903 Q903B Q903A 2SA1488 Y RL591 6 3 4 5 2 1 RL592 6 3 4 5 2 1 R911 JUMPER Q902A 2SC3851 Y Q902 Q902B RL450 1 4 9 P502 PHONES 3 2 1 C519 104J R569 22 R545 22K L501 J691 NC R555 1W 8 2 C517 473J P511 1 2 R513 56K R591 1 4W 2 2 Q519 2SA1930 Q517 2SC5171 R553...

Page 6: ...865 1K R866 1K R868 220 Q802 2 I 1 G 3 O JL211C 3 2 1 JL211A 1 2 3 4 5 6 7 8 9 10 JL212A 5 4 3 2 1 P801 8 7 6 5 4 3 2 1 P802 6 5 4 3 2 1 R820 10K Q812 RN2402 R819 10K R812 10K JL811A 1 2 3 C804 100 16 C803 10 50 R814 220K R815 220K R830 1K R822 47 Q801 uPD78F0533GK 17 P60 SCL0 18 P61 SDA0 19 P62 EXSCL0 20 P63 21 P33 TI51 TO51 INTP4 22 P77 KR7 23 P76 KR6 24 P75 KR5 25 P74 KR4 26 P73 KR3 27 P72 KR2 ...

Page 7: ...6 5 14 4 13 3 2 1 JL812B 10 9 8 7 6 5 4 3 2 1 R851 270 R850 330 R878 150 R877 150 R876 150 R875 150 R874 150 R873 150 Q838 RN1402 Q837 RN1402 Q836 RN1402 Q835 RN1402 Q834 RN1402 833 02 D838 R848 560 R849 470 R843 3 3K R842 6 8K R847 680 R846 1K R845 1 2K R844 1 8K R841 18K JL813B 3 2 1 D805 JL913B 1 2 3 4 5 R200 3 9 7 8 2 M C781 223 C782 223 C784 223 C783 223 R783 1K R782 470K JL210A 5 4 3 2 1 AAF...

Page 8: ...ONLY WITH FUSE OF SAME TYPE CAUTION ATTENTION ET CALIBRATION COMME INDIQUE D INCENDIE REMPLACER UNIQUEMENT PERMANENTE CONTRE LES RISQUES AFIN D ASSURER UNE PROTECTION PAR UN FUSIBLE DE MEME TYPE V A E LENT POUR UNE PROTECTION PERMANENTE N UTILISER INDIQUE LA QU LE PRESENT SYMBOL EST APPOSE QUE DES FUSIBLES DE MEME TYPE CE DARNIER EST CE SYMBOLE INDIQUE QUE LE FUSIBLE UTLISE EST FOR CONTINUED PROTE...

Page 9: ...EDURE A 9155 B A 9155 B A 9 1 5 5 B L R A951 A952 A953 A954 A509 A801 A506 A512 A751 A506 A500 A509 A701 A701 A752 A503 R L Front side marking Right side marking Front side Front side marking Left side marking Front side ...

Page 10: ...tp www us onkyo com ONKYO EUROPE ELECTRONICS GmbH Liegnitzerstrasse 6 82194 Groebenzell GERMANY Tel 49 8142 4401 0 Fax 49 8142 4401 555 http www eu onkyo com Sales Product Planning Div 2 1 Nisshin cho Neyagawa shi OSAKA 572 8540 JAPAN Tel 072 831 8023 Fax 072 831 8124 ONKYO CORPORATION http www onkyo com HOMEPAGE ONKYO CHINA LIMITED Units 2102 2107 Metroplaza Tower I 223 Hing Fong Road Kwai Chung ...

Reviews: