GND_DG
ACPOWER
+12V
SUB_DG
POFF
L_TAP
+15V
GND_15V
+4V
GND_4V
+12V
GND_DG
L_TAP
25
24
23
22
21
20
19
18
17
16
6
5
4
8
9
7
1
2
12
11
10
14
13
15
PS SECTION
SCHEMATIC DIAGRAM (PART 10/10)
Model No.A-9000R/A-9070
to MICON
NPT-1612
S3
P TRANS
S3a
S1
HOT
COLD
to DG
to PRE
to DISPLAY
S4
S6
S5
*
S1a
THERMAL FUSE
PVC
325ohm,27.7mA
*
*
M3R014C
R9002
T9501
134mA
BROWN
BLACK
GRAY
WHITE
BROWN
BLACK
GRAY
WHITE
360ohm,33.3mA
P6503C
P9513A
P9519A
Lch
*
*
*
*
18000uF
C9513/14/15/16
A-9000R
15000uF
A-9070
P9514A
P9520A
P6504C
Rch
BAPS-0981 TAP
BAETC-0979 BLOCK C
BAPS-0977 PS
A-9000R ONLY
*
BASW-0978 ACSW
*
BROWN
WHITE
EXCEPT DC,PR
250V 5A/80A
S2
S2a
*
A-9070 ONLY
47K
47K
47K
68K
R9008
R9002
-
-
-
J9002,J9003
-
T9501
MPP
MGR
MJJ
-
MDC
-
T2.5AL-250V
T2AL-250V
6.3A-125V
6.3A-125V
F9001
NPT-1520JQ
NPT-1520JQ
T9001
NPT-1520GQ
NPT-1520GQ
NPT-1612M
NPT-1612M
NPT-1612J
NPT-1612D
A-9000R
A-9070
J9001
-
-
P9002 , BASW-0978
D9007
1SS352
D9008
1SS352
D9012
1SS352
D9011
1SS352
D9002
1SS352
D9003
1SS352
D9006
1SS352
D9004
1SS352
AC_CABLE
F9001B
F9001A
NSCT-1P2031
C9002
104J
RL9001
NRL-1P10A-DC9-186
1
2
3
4
Q9001
KRC105S
D9014
1SS352
R9012
15(1/2W)
D9010
1SS352
R9010 10K
C9007
104J
C9011
104J
R9009
47K
C9003
10/50
C9010
104Z
Q9002
NJU7706F27A3
5 VDD
1 VSS
2
VSS
3
NC
4
OUT
D9001
1SS355
R9013
22K
R9014
47(1/2W)
D9013
S1NB60-4062
4
3
1
2
D9009
S1NB60-4062
4
3
1
2
P9005B
NPLG-5P119
5
4
3
2
1
P9007A NSAS-6P2004
1
2
3
P9001B
NPLG-2P632
2
1
C9004
470/25
C9015
470/25(UTSP)
C9009
470/25(UTSP)
C9012
1000/10(VR)
C9016
1000/10(VR)
C9014
1000/16
C9008
1000/16
T9001
NPT-1520
4
1
6
5
8
9
P9004A
1
C9006
104J
P9004B
1
P9006A
NPLG-5P352
1
2
3
4
5
P9003B
NPLG-2P631
2
1
P1003B NSAS-14P2012
1
2
3
4
5
6
7
R9003
1A-TUL-125V
2
1
R9011
1A-TUL-125V
2
1
R9004 100K
R9008
47K
C9005
RE275V-103M
R9005150(1/2W)
J9002
J9003
P9502B
NPLG-7P154
1
2
3
4
5
6
7
C9504 104J
RL9504
NRL-1P10A-DC12-198
4
3
5
2
1
RL9502
NRL-1P10A-DC12-198
4
3
5
2
1
C9502 104J
P9501B
NPLG-7P154
1
2
3
4
5
6
7
D9504 1SS355
D9502
1SS355
P9007B
NPLG-3P350
3
2
1
Q9003
KRC105S
RL9503
NRL-1P10A-DC12-198
4
3
5
2
1
D9503 1SS355
C9503
104J
C9501 104J
D9501
1SS355
RL9501
NRL-1P10A-DC12-198
4
3
5
2
1
Q9004
KRC105S
P9504D
NSAS-8P2019
1
P9504C
NSAS-8P2019
1
P9504B
NSAS-8P2019
1
P9504A
NSAS-8P2019
1
P9503D
NSAS-8P2019
1
P9503C
NSAS-8P2019
1
P9503B
NSAS-8P2019
1
P9503A
NSAS-8P2019
1
R9001
4.7(1/2W)
C9513
LIST
+
C9515
LIST
+
P9503E
NPLG-4P151
4
3
2
1
C9514
LIST
+
C9516
LIST
+
P9504E
NPLG-4P151
4
3
2
1
P9515B
2 3 4
1
P9516B
2 3 4
1
P9512B
2 3 4
1
P9511B
2 3 4
1
C9506
334J/100V
C9508
334J/100V
C9510
334J/100V
C9512
334J/100V
C9511
334J/100V
C9509
334J/100V
C9507
334J/100V
C9505
334J/100V
D9508
BR64
1
3
4
2
D9506
BR64
4
3
1
2
D9507
BR64
1
3
4
2
D9505
BR64
4
3
1
2
P9002C
NPLG-2P631
2
1
S9001
NPS-111-L687P(TV-5)
J9001
P9002B
1
P9002A
NSAS-4P1999
1
ARE CRITICAL FOR SAFETY.
+
* THE COMPONENTS IDENTIFIED BY MARK
* VOLTAGE (MEASUREDWITHVOLTMETER) ISDCVOLTAGE. (NO INPUT SIGNAL)
* ELECTROLYTIC CAPACITORS ( ) ARE IN uF/WV.
* ALL CAPACITORS ARE IN pF/50WV UNLESS OTHERWISE NOTED.
* CIRCUIT IS SUBJECT TO CHANGE FOR IMPROVEMENT.
REPLACE ONLY WITH PART NUMBER SPECIFIED.
CAUTIONF AFIN D'ASSURER UNE PROTECTION
PERMANENTE CONTRE LES RISQUES
D'INCENDIE, REMPLACER UNIQUEMENT
PAR UN FUSIBLE DE MEME TYPE
ET CALIBRATION COMME INDIQUE.
ATTENTION
V
A
A
V
CAUTION
AND RATING INDICATED.
ONLY WITH FUSE OF SAME TYPE
AGAINST FIRE HAZARD, REPLACE
FOR CONTINUED PROTECTION
CE SYMBOLE INDIQUE QUE LE FUSIBLE UTLISE EST
A LENT, E POUR UNE PROTECTION PERMANENTE,N'UTILISER
QUE DES FUSIBLES DE MEME TYPE. CE DARNIER EST
INDIQUE LA QU LE PRESENT SYMBOL EST APPOSE.
THAT THE FUSE USED IS SLOW OPERATING TYPE
RATING REFER TO THE MAKING ADJACENT TO THE SYMBOL.
THIS SYMBOL LOCATED NEAR THE FUSE INDICATES
FOR CONTINUED PROTECTION AGAINST FIRE FUSE
HAZARD,REPLACE WITH SAME TYPE FUSE. FOR FUSE
A
1
2
3
4
5
B
C
D
E
F
G
H
A-9000R / 9070
Schematic Diagrams - 10
Power Supply