FP-4400 PORTABLE CLAMP-ON ULTRASONIC FLOW METER
ONICON Incorporated 727.447.6140
Page 34 onicon.com
BATTERY INFO
The Battery Info page is used for diagnostic purposes, and is not used for any
configuration of meter behavior.
Battery Voltage
– Shows the battery voltage in volts (V).
Battery Current
– Shows the charge (positive) or discharge (negative) current in
milliamps (mA).
Battery Level
– Shows the battery fuel gauge charge percent. Matches the
percentage shown on the Main Display and Messages page.
USB Voltage
– Shows the voltage on the USB connector. Typically 3.2 V when no
charger is connected, and 5.0 V when a charger is connected.
USB Current
– Shows the current from the external USB-C charger.
Charge Current
– Shows the current into the battery.
USB Device
– Shows the state of the USB connection: None, Charger, Drive
Battery Info
Battery Current
Battery Voltage
Battery Level
USB Voltage
USB Current
Charge Current
USB Device
-405.9 mA
4.095 V
98%
3.200 V
0 mA
0 mA
None
Configuration
Utility
Serial#
Transit Time
Bootloader
1.1.11.g
000012345
2.7.1
1.2
CONFIGURATION
The Configuration page shows the serial number of the FP-4400, and the
firmware versions of the utility board, transit time board, and bootloader.
ONICON may ask for this information to help diagnose measurement questions.