background image

Install Analog Clock: 12.5" dual-sided electric powered

A dual-sided analog clock consists of two single analog clocks and a dual clock kit. Using the kit you combine the two
clocks to create a dual-sided clock, which can be either ceiling or wall mounted.

Supplied components

Quantity

Component

1

Dual mount bracket

1

Mounting plate

Screws and anchors supplied with each clock are included in the order packaging.

Step 1: Assemble clocks to dual mount bracket

1. Place each clock in the housing with the 10/11 and 4/5 numerals over the brass posts.

2. Route the clock power cords to the left, right, or center position. For right or left routing, remove the dual mount

bracket cover and thread the cord through the clearance hole in the bracket. Lift the power cord out of the way,
then slide the bracket cover back onto the dual mount bracket.

3. Place your hands at the 10/11 and 4/5 positions and turn the clock clockwise to lock into place. Repeat this step

for each of the two clocks.

Page 11

Summary of Contents for B1004Z

Page 1: ...OneVue Sync Bluetooth Analog Clock Install Guide Product Models B1004Z Publication date February 19 2020 ...

Page 2: ... respective owners The Bluetooth word mark and logos are registered trademarks owned by the Bluetooth SIG Inc and any use of such marks by Primex Inc is under license Primex is the leading provider of solutions to automate and maintain facility compliance increase efficiencies enhance safety and reduce risk for enterprise organizations in the healthcare education manufacturing and government verti...

Page 3: ...ed 11 Step 1 Assemble clocks to dual mount bracket 11 Step 2 Mount bracket kit to wall or ceiling 12 Analog clock Remove from clock lock mount 13 Dual sided Analog Clock Remove from dual mount bracket 14 Reassemble clocks to dual bracket 14 Analog Clock battery maintenance 15 Battery use requirements 15 Replace batteries for an analog clock 15 Specifications Sync Bluetooth Analog Clock 16 Technica...

Page 4: ...etooth mesh network It may take up to 15 minutes for a device to authenticate and connect to an available mesh network We recommend to continue installing additional devices while other devices establish their connection to the mesh network 2 Once a device has authenticated with the mesh network it establishes a communication path either to another Sync Bluetooth device or directly to a Bridge ava...

Page 5: ...cts to your facility s network to receive UTC time from a NTP Server and check in to OneVue to download device setting updates 2 Once a day at a system defined time each Sync Bluetooth device automatically establishes a wireless communication path to either another device to build the Sync Bluetooth mesh network Clock and repeater statuses are forwarded to a Bridge either by its communication path...

Page 6: ...0V AC powered clocks are supplied with a power cord with a two prong plug The two prong plug may be removed for a hardwired pigtail installation Hardwired installation requires a 120V power line in a junction box installed by a licensed electrician Leave a minimum of 6 inches 15 2 cm of cord inside the junction box Battery use recommendations Battery life expectancy is based on common operating co...

Page 7: ... met 2 Drill holes for the screw anchors at the spacing listed in the following table If two screws are being used to secure the clock to the wall using the clock lock mount the distance between the screws is precisely the same as the hole spacing specified below You may download an analog clock hanger template for a full scale template of the hole spacing Model Hole Spacing Mounting Type 12 5 Rou...

Page 8: ...7 Slide the clock down over the screw heads to latch it into place When a clock or repeater is powered on it enters Add a Clock Mode to initiate a connection to the Sync Bluetooth mesh network Page 8 ...

Page 9: ...der packaging Step 1 Mount plate to wall or ceiling and assemble bracket 1 Measure and drill holes on the wall or ceiling to meet the spacing dimensions of the supplied mounting plate as shown in the figure below 2 Attach the mounting plate to the wall ceiling using the provided anchors and screws The mounting plate holes are to line up with the holes drilled in the wall ceiling 3 Slide the dual c...

Page 10: ...assemble the clocks to the bracket 1 Apply power to the clock 2 Press and release the button located on the back of each clock to initiate its connection to a in range Sync mesh network to receive its time 3 Place the clock in to the bracket housing with the 10 11 and 4 5 numerals over the metal posts 4 Place your hands at the 10 11 and 4 5 positions and turn the clock clockwise to lock into place...

Page 11: ... the order packaging Step 1 Assemble clocks to dual mount bracket 1 Place each clock in the housing with the 10 11 and 4 5 numerals over the brass posts 2 Route the clock power cords to the left right or center position For right or left routing remove the dual mount bracket cover and thread the cord through the clearance hole in the bracket Lift the power cord out of the way then slide the bracke...

Page 12: ...e provided anchors and screws 3 Slide the assembled dual clock bracket over the four tabs on the mounting plate A tap with a rubber mallet on the clock bracket may be required to set the clock bracket assembly fully into place 4 Route the power cords as desired and apply AC power When a clock or repeater is powered on it enters Add a Clock Mode to initiate a connection to the Sync Bluetooth mesh n...

Page 13: ...Analog clock Remove from clock lock mount Follow the illustrated steps below to remove a clock from a clock lock mount Page 13 ...

Page 14: ...t the 10 11 and 4 5 positions Turn each clock counter clockwise to unlock the clock housing from the twist lock mount Reassemble clocks to dual bracket 1 Place clock in the housing with the 10 11 and 4 5 numerals over the brass posts 2 Place your hands at the 10 11 and 4 5 positions and turn the clock clockwise to lock into place Page 14 ...

Page 15: ...te five or more years beyond the installation date Use batteries with the same type and date code Do not use heavy duty and zinc carbon batteries as they will not last as long as high quality name brand alkaline batteries Do not use rechargeable NiCad batteries as their output voltage is too low to assure proper operation Do not use standard lithium batteries Battery level is monitored by OneVue B...

Page 16: ...omatically connects daily to an available Sync Bluetooth mesh network to receive UTC time and synchronize its time to its Time Zone offset and DST rules downloads OneVue setting updates and send its current operating status Automatically adjusts for Daylight Saving Time DST Automatically performs a daily midnight hand verification check When check fails for three 3 consecutive days the clock enter...

Page 17: ...x products If you have purchased Primex products or have a service agreement with a Primex Partner they are your primary contact for all Technical Support inquires Primex Technical Support Make sure you have satisfied the system requirements that are listed in your product documentation Also you should be at the computer or device on which the problem occurred in case it s necessary to replicate t...

Page 18: ...n wet areas is an electrical hazard and may damage the equipment while nullifying the warranty Device is cleanable with a cloth moistened with water or a common disinfectant Be sure to test any cleaning solutions on a small area of the clock before using it on the entire device Do not use caustic cleaners or abrasives Keep away from dust dirt and moisture For healthcare facilities devices are not ...

Page 19: ...er is connected Consult the dealer or an experienced radio TV technician for help To assure continued appliance any changes or modifications not expressly approved by the party responsible for compliance could voice the user s authority to operate this equipment Example use only shielded interface cables when connecting to computer or peripheral devices FCC Warning Any Changes or modifications not...

Page 20: ...ch provides the least interference and best performance In the USA and Canada 11 channel are available If using multiple Access Points it is better if adjacent Access Points use different Channels to reduce interference In Infrastructure mode Wireless Stations normally scan all Channels looking for an Access Point If more than one Access Point can be used the one with the strongest signal is used ...

Page 21: ...ubi même si le brouillage est susceptible d en compromettre le fonctionnement The device meets the exemption from the routine evaluation limits in section 2 5 of RSS 102 and compliance with RSS 102 RF exposure users can obtain Canadian information on RF exposure and compliance Le dispositif rencontre l exemption des limites courantes d évaluation de routine dans la section 2 5 de RSS 102 et la con...

Page 22: ...radio equipment and services Part 17 Specific Conditions for Wideband Data and HIPERLAN Equipment EN 60950 Low Voltage Directive Safety EN 50385 Product standard to demonstrate the compliances of radio base stations and fixed terminal stations for wireless telecommunication systems with the basic restrictions or the reference levels related to human exposure to radio frequency electromagnetic fiel...

Page 23: ... This warranty is VOID if this product has been altered or modified in any way including but not limited to attempted warranty repair other than by Primex or an authorized service partner Limitation of Liability The warranties and remedies contained herein are exclusive and in lieu of all other warranties express or implied or statutory including any liability arising under any warranty or merchan...

Reviews: