24
Chapter 3:
Using Easy Print Mode
O’Neil Programming Language Reference Manual
Print Command: Customizing Bar Codes
Bar Code Names
{Print, Global Options:@row,column:NAME,Field Options|data|}
Use the following options to customize a bar code:
Bar Code Field Options
{Print, Global Options:@row,column:Name,FIELD OPTIONS|data|}
Name
Description Requirements for Data
BC39N
Code 39
2:1 ratio
Use the following characters in the data field:
Space $ % + . / 0-9 A-Z
Auto inserts leading and trailing asterisk (*).
BC39W
Code 39
3:1 ratio
Use the following characters in the data field:
Space $ % + . / 0-9 A-Z
Auto inserts leading and trailing asterisk (*).
COBAR
Codabar
0-9 - $:/.a b c d. You must send leading and trailing guard bar
a-d.
I2of5
Int (?) 2 of 5
2.5:1 ratio
0-9 (Digits only, must be even. Controller inserts leading zero
to ensure an even number of digits.)
BCI25 Int. (?) 2 of 5
2:1 ratio
0-9 (Digits only, must be even. Controller inserts leading zero
to ensure an even number of digits.)
BC128
Code 128
Automatically selects codes A-C for the shortest bar code.
Allows all ASCII characters.
EN128
EAN-128
Uses codes C for the shortest bar code. Allows all ASCII
characters.
UPC-A
UPC-A
0-9 (Must have 11 digits or error. Controller calculates check
digit.)
EAN08
EAN-8
0-9 (Must have seven digits or error. Controller calculates
check digit.)
EAN13
EAN-13
0-9 (Must have 12 digits or error. Controller calculates check
digit.)
PD417
PDF-417
For more information, see ___.
Field
Option
Abbreviation Description
HIGHn
H nn
Changes the height of the bar code in five dot-inch intervals.
The default is five dots; 1<n<255.
WIDEn
W nn
Width multiplier of the bar code. Default is one; If W=2, W is
twice as wide (1/2 density) as W=1; 1<n<255.
Summary of Contents for microFlash2
Page 3: ......