background image

8

OAS Vortex DCS Owner’s Manual     O.A.S. 2013

c

1

2

3

4

2a

1

3

4

5

6

4a
4b

2b

2

Cyclone Box Should Contain 

All of the Items to the Left.

Weight: 20 lbs.

18” x 16” x 14”

Parts List for Vac System Kits

1. Sander Cyclone Barrel Assembly - VXCSXZ000
2. HEPA Filter - Sander - Assembly with Cleaner - VSFSHC000
    2a. Sander HEPA Filter 15.3 Sq. Ft. - VSFSHZ000
    2b. Filter Cleaner Assembly - VSFCSZ000
3. Clamp 8” Dia. & Pin - VRR080000
4. Sander Cyclone Cone Assembly - VRS080111
    4a. Clear Cone - VRS080110
    4b. Metal Base for Clear Cone - VXS080110
5. Pipe Clamp 2.5” Regular (Standard) - VSACPZ250
6. Heavy Duty Pipe Coupler 2.5” (optional) - VSACPH250

Sander HEPA Cyclone Kit - VSKCSZ000

1. Sander Cyclone HEPA Filter with Cleaner Assembly - VSFSHC000
2. Sander Cyclone / Vac Pump HEPA Filter - VSFSHZ000
3. Edger HEPA Filter with Cleaner Assembly - VSFEHC000
4. Edger HEPA Filter - VSFEHZ000

HEPA Filters - Gore filter media rated to capture 

99.97% down to 0.3 microns

1. Sander Cyclone Filter with Cleaner Assembly - VSFSSC000
2. Sander Cyclone / Vac Pump Filter - VSFSSZ000
3. Edger Filter with Cleaner Assembly - VSFESC000
4. Edger Filter - VSFESZ000

Filters - Non-HEPA Spun-Bond Polyester

Vac Retrofit Adaptors

5”

Essex Silverline

Pro 8

Taurus

Handle

Hummel

Handle

Clarke EZ8

Bona Universal

Stack

Bona Pro Sand 8

Super Bee

*Refer to installation sheets for retrofit instructions.

VSRSES000

VSRSKT000

VSRSLH000

VSRSEZ000

VSRSBU000

VSRSBP080

Includes

2 1/8” Tube Clamp

VRC002125

VSRSCU000

Includes

2 1/8” Tube Clamp

VRC002125

Galaxy 2000

VXA025020

Need 2.5” clamp

Part # VSACPH250

Only needed 

if sander dust 

outlet is under 

2.5” O.D.

Lagler Trio Retrofit Kit

VSRSLT000

Includes:

VXA040000 - Lagler Trio Retrofit

VSACPH250 - 2.5” Clamp

Summary of Contents for Vortex DCS

Page 1: ...5 Sander Not Included The most effective portable floor sanding dust containment system with patented vortex technology Vortex Gorilla Vac Dust Containment System TM Oneida Vortex DCS TM Dust Containm...

Page 2: ...m the outside See cleaning procedure on pg 6 Do not overfill Dust Bin Check regularly Do not operate collector in flammable atmosphere i e Finish fumes Caution Fine dust is the most hazardous to breat...

Page 3: ...In order to facilitate your transition to using our system makesure all people using the system read the Owner s Manual The information provided is very important to the day to day opera tion of the d...

Page 4: ...idge Be careful not to damage filter Clamps Cyclone 90 Elbow T Clamp Connect Cyclone to Floor Sander Dust Outlet with Provided T Clamp Connection should be air tight Connect Cone outlet to Flex Hose o...

Page 5: ...st collector is running efficiently Follow filter cleaning instructions on pg 3 Oneida s filters are extremely durable and reusable Their lifespan is normally between 40 100 jobs Regular and thorough...

Page 6: ...ence a clog in the hose reverse the flow of air through the hose by hooking the other end up to the vacuum If this doesn t work blow one end out with compressed air outside If it still persists work t...

Page 7: ...rs must be cleaned before or after every job This is VERY important System will not work unless filters are clean Best Way to Clean Filters At least 3 away Turn crank up and down filter Blow off filte...

Page 8: ...HEPA Filter VSFSHZ000 3 Edger HEPA Filter with Cleaner Assembly VSFEHC000 4 Edger HEPA Filter VSFEHZ000 HEPA Filters Gore filter media rated to capture 99 97 down to 0 3 microns 1 Sander Cyclone Filte...

Reviews: