XI. Filter Maintenance
External Filter Cartridge Cleaning Intervals
When unit is turned off, use compressed air to blow dust off from
exterior of filter. Hold nozzle at least 6” away from filter pleats*.
Do not remove bottom dust pan before or during the blow-off
process! Let dust settle into dust pan. Unclip and dump out dust.
Filter removal is not required.
*WARNING: A close, direct blast with the compressed air nozzle
too close to filter, may damage filter media. Always wear safety
glasses while blowing off filter.
Fan / Blower & Cyclone Outside Placement
Fan / Blower has a TEFC - Totally Enclosed Fan Cooled Motor.
Note: Use steel drum when placed outside.
Before Operation:
Mount system and connect cyclone and dust bin. Make sure dust bin is in place and ductwork is connected
to inlet before turning on the dust collector.
Electrical Wiring:
Make sure power source matches wire voltage configurations on motor.
Prior to connecting to the power line, check motor plate for proper voltage.
Motor is pre-wired for counter-clockwise rotation. Fan wheel must rotate
counter-clockwise if looking down on fan housing.
Use 12 gauge cord for the fan / blowers.
Lubrication:
See pg. 15 for schedule and specifications.
Caution: Rotating Fan Blades! Keep objects clear of outlet.
Do not operate Fan / Blower unless Cyclone and Dust Bin are in place! Motor will overheat!
Caution: Fine dust collected in filter is hazardous to
your health! Do not breathe!
Shown with
optional Stand.
Attach the ring terminal on the green
ground wire from the motor to a bolt on the
filter plate, under the nut. Then attach the
alligator clip to the filter cage as shown in
Fig. 1.
Figure 1
Filter Grounding Wire
5hp Systems
require a 30