background image

VI.  Assembly Instructions

O.A.S. 2002

c

5 - 7.5 HP Direct Drive Owner’s Manual

Cyclone
Barrel

Cyclone
Barrel

Air Inlet

Fan / Blower

1.

1. Orient the blower housing to match the stand
configuration and the desired angle for the cyclone inlet.
Bolt the fan / blower to the cyclone barrel using the
hardware taped on the motor.
Bolts are already welded on Fan/Blower unit. Put a bead
of silicone around top hole in cyclone barrel, then put
bolts through holes in barrel. Put flat washer on bolt.
then lock washer, then hex nut.

Cyclone
Cone

2.

3.

2. Bolt the fan housing and cyclone barrel to the cyclone
cone using hardware taped to cyclone barrel. Note: the
fan / blower and the cyclone barrel are very heavy. The
system will be top heavy. One method is to lay the stand
down, then bolt the cyclone with the fan / blower to the
stand. The iron ring will be on top of the cross bars of
the stand. Put bead of silicone around inside edge of
flange on the cyclone cone. Then put bolt through flat
washer, then bolt through holes in both flanges, thenput
lock washer on bolt, then attach hex nut.

Cyclone Inlet and Fan / Blower are independent.
Filters can be to the right or left of the unit.

3. Tip the fan housing and cone upright. The system is
very top heavy. Place plenum on top of the plenum
stand.

4. Bolt the plenum to the fan housing outlet (rectangular).
Clamp the cartridges to the plenum. Clamp the dust
bins to the bottom of the cartridge filters.

Plenum

Stand

Cartridge
Filters

Dust Bins

Outlet

Air
Outlet

Continued on next page.

7

Silicone
Bead

Silicone
Bead

Bolt

Flat Washer

Flange

Lock Washer

Hex Nut

16 ea. 3/8” Flat Washers, Lock Washers and Hex Nuts

16 ea. 3/8” Flat Washers,
Lock Washers, Hex Nuts
and 3/8 x 1” Bolts

Fan / Blower is shipped strapped to Cyclone Barrel. It is NOT
attached to the unit. You must bolt them together. Follow the
instructions below.

Summary of Contents for 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors

Page 1: ...5 7 5 HP Direct Drive Cyclonic Dust Collectors Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual...

Page 2: ...e ofContents Page Read the entire Owner s Manual before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII XIV 2 3 4 5 6 7 8 8 9 10 11 12 13 14 15 System Start Up Information Di...

Page 3: ...nual 4 Have a licensed electrician check current draw on motor with all gates open Current draw should not exceed maximum motor amperage OAS is not responsible for destroyed motors Caution The Direct...

Page 4: ...gases carbon monoxide can be drawn into the shop from furnaces water heaters or other appliances 2 External Cartridge Filters 3 External Tube Filter O A S 2002 c 5 7 5 HP Direct Drive Owner s Manual...

Page 5: ...filter media BIA ZHI 487 test Rated G Captures 99 of test material over 20 microns Captures 99 5 of test material between 0 2 2 0 microns 11 fpm face velocity Tube Filter Bags 2 Pleated Cartridges 260...

Page 6: ...39 1 4 62 73 1 8 12 12 32 1 8 O D of Mounting Ring 69 875 24 1 4 Bolt Holes 30 3 8 10 031 I D 7 64 I D 1 25 Flange Tube Filters Height for 8 bags Other heights available 131 w 55 gal steel drum 105 No...

Page 7: ...race for Cyclone Angle Ring to sit on 1 Choose the system orientation plenum can be on the right or the left of the cyclone Bolt together the stand using the cross bars and 3 8 x 1 bolts Note the cros...

Page 8: ...iron ring will be on top of the cross bars of the stand Put bead of silicone around inside edge of flange on the cyclone cone Then put bolt through flat washer then bolt through holes in both flanges...

Page 9: ...ocedures could result in serious injury or death Disconnect all power and discharge all capacitors before servicing Install and ground per local and national codes Consult a licensed electrician with...

Page 10: ...n plastic bucket and tube filter to fit properly underneath A well sealed plywood box will make a good plenum for air distribution through the tube filters Use plywood for the plenums Cut 12 dia holes...

Page 11: ...ring the blow off process Let dust settle into dust pan Unclip and dump out dust Filter removal is not required You can also run your fingers around the filter pleats to knock material down WARNING A...

Page 12: ...licensed electrician Ground Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw 11 Top View Outlet Inlet O A S 2002 c 5 7 5 HP Direct Drive O...

Page 13: ...5 and 7 5hp direct drive dust collectors do not come wired or with an on off switch Because of the voltage and amperage requirements of the system an industrial switch must be used OAS offers Square...

Page 14: ...nd as a sealant Check for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check fo...

Page 15: ...elow 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an e...

Page 16: ...warrants In no event shall O A S s liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of...

Reviews: