background image

NIS54xxGEVB

 

 

http://onsemi.com

 

Figure 2:  Schematic for the evaluation board. 

 

 

The user’s manual is divided into two sections.  The first section is for the NIS5431 3.3 V series of devices.  

The second section covers the NIS545x 5 V series of devices.  For these devices ensure that J1 is in the “54xx” 
position.   
 

 

Figure 3:  Features of the evaluation board. 

Summary of Contents for NIS54 Series

Page 1: ...D USER S MANUAL This evaluation board has many features which make it simple to observe the functionality and performance of the new NIS54xx line of eFuses Multiple connectors available for all eFuse...

Page 2: ...rd The user s manual is divided into two sections The first section is for the NIS5431 3 3 V series of devices The second section covers the NIS545x 5 V series of devices For these devices ensure that...

Page 3: ...voltage drop of 6 2 V the device will reach its thermal shutdown point and latch off The green indicator LEDs will turn off and the yellow fault indicator LED will be on An auto retry eFuse MT2 part...

Page 4: ...ly cycles the enable pin For auto retry eFuses the demo board s green and yellow indicator enable pin indicator LEDs will flash as the enable pin cycles between states Figure 5 This test shows how the...

Page 5: ...will be limited to the short circuit current limit level After some time the device will enter thermal shutdown due to the high current and voltage between VCC and source output voltage pins An auto r...

Page 6: ...controlled slew rate changes When J6 is in place the slew rate will be longer because a capacitor is connected between the dv dt pin and GND With VCC set to 3 3 V press and release the blue button to...

Page 7: ...the 3 3 V power cable and plug it into the demo board Observe that the eFuse turns on with no issue and the output voltage rises in a controlled fashion Figure 8 This shows a standard hot plug test Th...

Page 8: ...ches the thermal shutdown level and latches off An auto retry eFuse MT2 part number suffix does not latch and automatically cycles the enable pin For auto retry eFuses the demo board s green and yello...

Page 9: ...age drop of 4 V the eFuse will reach its thermal shutdown point and latch off The green indicator LEDs will turn off and the yellow fault indicator LED will be on An auto retry eFuse MT2 part number s...

Page 10: ...able pin For auto retry eFuses the demo board s green and yellow indicator enable pin indicator LEDs will flash as the enable pin cycles between states Figure 11 This test shows how the enable pin is...

Page 11: ...l be limited to the short circuit current limit level After some time the device will enter thermal shutdown due to the high current and voltage between VCC and source output voltage pins An auto retr...

Page 12: ...controlled slew rate changes When J6 is in place the slew rate will be longer because a capacitor is connected between the dv dt pin and GND With VCC set to 5 V press and release the blue button to se...

Page 13: ...he 5 V power cable and plug it into the demo board Observe that the eFuse turns on with no issue and the output voltage rises in a controlled fashion Figure 14 This shows a standard hot plug test The...

Page 14: ...the thermal shutdown level and latches off An auto retry eFuse MT2 part number suffix does not latch and automatically cycles the enable pin For auto retry eFuses the demo board s green and yellow in...