Jumper/Header Functions & Default Positions

Table 1. JUMPERS AND HEADERS 

 

Jumper/Header No.

Jumper/Header Name

Pins

Description

P1

TEST

1

2 (Default)

MIPI/Parallel Output Enabled

2

3

CCP Output Enabled

P2

ATEST

Open (Default)

For Debug/Test

P3

FLASH

Open (Default)

For Connection to External Flash

P4

GPIO

Open (Default)

For Connection to Various Sensor Settings

P5

SHUTTER

Open (Default)

For Connection to External shutter

P6

+2V8_VAA

1

2 (Default)

Connects to On-board +2V8_VAA Power Supply

2

3

External Power Supply Connection

P7

+VCM

Open

For Connection to ExVCM Supply

P8

+1V8_VDD

1

2 (Default)

Connects to On-board +1V8_VDD Power Supply

2

3

External Power Supply Connection

P9

+1V2_VDD

2

3 (Default)

Connects to On-board +1V2_VDD Power Supply

1

2

External Power Supply Connection

P10

+1V2_VDDPLL

2

3 (Default)

Connects to On-board +1V2_VDDPLL Power Supply

1

2

External Power Supply Connection

P11

+VPP0

Open (Default)

For OTPM Programming

P12

CLK_SELECT

1

2 (Default)

On-board Oscillator (25 MHz)

2

3

Demo 3 Headboard MCLK

SW1

ON_LED

On (Default)

Turn On +5V LED Indicator

Off

Turn Off +5V LED Indicator

SW2

RESET

N/A

When Pushed, 400 ms Reset Signal will be Sent to

AR0832

SW3

EEPROM Addr. Sel

A0 ON, A1 ON, 

A2 OFF, WP ON

(Default)

EEPROM Address Set to 0xA8

A0 OFF, A1 OFF, 

A2 OFF, WP ON

EEPROM Address Set to 0xAC

A0 ON, A1 OFF, 

A2 ON, WP ON

EEPROM Address Set to 0xA4

A0 ON, A1 ON, 

A2 ON, WP ON

EEPROM Address Set to 0xA0

Interfacing to ON Semiconductor Demo 2X Baseboard

The ON Semiconductor Demo 2X baseboard has a similar

26-pin connector which mates with P13 of the headboard.
The four mounting holes secure the baseboard and the
headboard with spacers and screws.

Shorted Jumpers for Power Measurement

Different supplies to the evaluation board are provided by

trace shorted jumper, for any voltage and power
measurements. To conduct current for current measurement

on a given power rail, cut the trace between the two pins of
their respective JP, and insert an ammeter prior to powering
up the system. The figure below shows where the trace to cut
is located.

Table 2. SHORTED JUMPER FOR POWER 

MEASUREMENT 

 

Jumper

Voltage (V)

P16 (+5V0)

5.0

Figure 8. Top and Bottom View of Shorted Jumper.

The Bottom View Shows the Trace Location to Cut for Current Measurement

Cut Here

Summary of Contents for AR0832MBSC25SUFAH-GEVB

Page 1: ... to the clock I Os and other miscellaneous signals Features Clock Input Default 25 MHz Crystal Oscillator Optional Demo 2X Controlled MClk Two wire Serial Interface Selectable Base Address Parallel Interface MIPI Interface ROHS Compliant Block Diagram Figure 2 Block Diagram of AR0832MBSC25SUFAH GEVB Sensor Voltage Level Shifter Demo2 Connector I2C Bus Repeater 2 x RJ45 Voltage Regulators Voltage F...

Page 2: ...t Jumpers 2V8_VAA P6 FLASH P3 RESET SW2 EEPROM ADDR SW3 1V8_VDD P8 GPIO P4 CLK_SELECT P12 TEST P1 VPP0 P11 VCM P7 1V2_VDD P9 ATEST P2 ON_LED SW1 1V2_VDDPLL P10 SHUTTER P5 Bottom View Figure 4 Bottom View of the Board Connectors Baseboard Connector P13 MIPI Connector J2 MIPI Connector J1 ...

Page 3: ...ost Side and Increases as it Moves to the Right Pins 1 4 Pin 1 Figure 6 Pin Locations and Assignments of Grouped Jumpers Pin 1 is Located at the Top Left Corner and Increases in a Zigzag Fashion Shown in the Picture Pins 1 and 2 Pin 1 Pins 3 and 4 Pins 5 and 6 Pins 7 and 8 Pins 9 and 10 Figure 7 EEPROM Switches in their Default Positions The First Switch A0 of SW3 is ON the Second Switch A1 is ON ...

Page 4: ...ard MCLK SW1 ON_LED On Default Turn On 5V LED Indicator Off Turn Off 5V LED Indicator SW2 RESET N A When Pushed 400 ms Reset Signal will be Sent to AR0832 SW3 EEPROM Addr Sel A0 ON A1 ON A2 OFF WP ON Default EEPROM Address Set to 0xA8 A0 OFF A1 OFF A2 OFF WP ON EEPROM Address Set to 0xAC A0 ON A1 OFF A2 ON WP ON EEPROM Address Set to 0xA4 A0 ON A1 ON A2 ON WP ON EEPROM Address Set to 0xA0 Interfac...

Page 5: ... support systems or any FDA Class 3 medical devices or medical devices with a similar or equivalent classification in a foreign jurisdiction or any devices intended for implantation in the human body You agree to indemnify defend and hold harmless onsemi its directors officers employees representatives agents subsidiaries affiliates distributors and assigns against any and all liabilities losses c...

Page 6: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information onsemi AR0832MBSC25SUFAH GEVB ...

Reviews: