Reflective Sensor Heads: FUN Mode Functions
Section 3-5
66
3-5-8
Monitor Focus Function
The linear output range and inclination for display values can be specified.
These are set by defining two output values for specified display values.
Refer
to
4-5-10 Setting the Monitor Focus
.
When the monitor focus function cannot be set correctly,
refer to
5-2-2 Unable to Set Monitor Focus
.
Examples: Monitor Focus 1
Note:
The zero reset is automatically cleared when the monitor focus is set.
20
20
20
Linear output
current
(mA)
Linear output current
(mA)
Linear output current
(mA)
4
4
80 mm: 4 mA
120 mm: 20 mA
60 80 120 140
60 70 120 140
Sensor display value
(mm)
Sensor display value
(mm)
Sensor display value
(mm)
60
140
For these settings:
For these settings:
70 mm: 18 mA
120 mm: 6 mA
18
6
4