Part Names and Functions
60
ZW-8000/7000/5000
User's Manual
Front view
●
Display
●
Control panel
No.
Names (light color)
Functions
1
HIGH indicator (orange)
The HIGH indicator is lit while judgment is resulted in HIGH (HIGH threshold value <
measured value).
2
PASS indicator (green)
The PASS indicator is lit while judgment is resulted in PASS (LOW threshold value
≤
measured value
≤
HIGH threshold value).
3
LOW indicator (orange)
The LOW indicator is lit while judgment is resulted in LOW (measured value < LOW
threshold value).
4
STABILITY indicator (green)
The STABILITY indicator is lit while the measurement area 1 is within the measuring
range.
It goes out if a measured value is out of the measuring range.
5
ZERO indicator (green)
The Zero Reset indicator is lit while the zero reset function is enabled.
6
ENABLE indicator (green)
The ENABLE indicator lights when the Sensor is ready for measurement.
It goes off when measurement is not possible (e.g. when the received light amount is
excessive or insufficient, when the Calibration ROM is not connected, or when
measurement is not being performed in FUNC mode).
7
Main display (white)
The main display shows measured values and/or function names.
8
Sub-display (green)
The sub-display shows additional information for measured values or setting values for
functions.
9
RUN indicator (green)
The RUN indicator is lit in the RUN mode, and goes out in the FUNC mode.
10
THRESHOLD-L indicator
(orange)
The LOW threshold value indicator is lit when the Sub-display indicates a LOW threshold
value.
11
THRESHOLD-H indicator
(orange)
The HIGH threshold value indicator is lit when the Sub-display indicates a HIGH threshold
value.
12
ECAT RUN indicator (green)
ECAT RUN indicator lights up when EtherCAT communication is established.
13
L/A IN indicator (green)
L/A IN indicator lights up when connected with the EtherCAT device.
Flashes when communication (data input) is performed.
14
L/A OUT indicator (green)
L/A OUT indicator lights up when connected with the EtherCAT device.
Flashes when communication (data output) is performed.
15
ECAT ERROR indicator (red)
ECAT ERROR indicator lights up when an EtherCAT communication error occurs.
No.
Names
Functions
16
ZERORST/ESC key
These keys function differently depending on operation modes.
7-3 Functions of Operating Keys p.222
17
←
(LEFT) key
→
(RIGHT) key
↑
(UP) key
↓
(DOWN) key
18
ZERO/SET key
19
Mode switching key
This key is used to switch between RUN (operation) mode and FUNC (adjustment) mode.
20
Node address setting switches
(hexadecimal representation)
These switches are used to set the node address as an EtherCAT communications
device.
The setting range is 0x01(1) to 0xFF(255).
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......