7-2 Search from Menu Tree
FUNC (adjustment) Mode Menu
: This is displayed only when the 2 area mode is selected in [Measurement Area].
* default value
Setting
Option/Setting Range
Pages
Sensing
setting
[SENS]
Measurement
cycle
[CYCLE]
Measurement
cycle
[CYCLE]
Refer to explanation page of
Measurement cycle
Material
[OBJECT]
Material
[OBJECT]
Normal [NORMAL]*/
Mirror surface [MIRROR]/
Diffusion surface [DIFF]
Area mode
[REG.MOD]
Area mode
[REG.MOD]
1 Area mode [1. MODE]*1/
2 Area mode [2. MODE]
Amount of
emitted light
[LIGHT]
Area1
[REG.NO1]
Auto*
[AUTO]
Upper limit
[MAX]
0.01 to 100.00%
(default value: 100%)
Lower limit
[MIN]
0.01 to 100.00%
(default value: 0.01%)
Surface to be
controlled
[ADJ.SUR]
Edge 1st [EDGE1]/Edge 2nd
[EDGE2]/Edge 3rd [EDGE3]/Edge
4th [EDGE4]/Peak [PEAK]*
Fixed
[FIXED]
Fixed value
[FIXED]
0.01 to 100.00%
(default value: 100%)
Area2
[REG.NO2]
Auto*
[AUTO]
Upper limit
[MAX]
0.01 to 100.00%
(default value: 100%)
Lower limit
[MIN]
0.01 to 100.00%
(default value: 0.01%)
Surface to be
controlled
[ADJ.SUR]
Edge 1st [EDGE1]/Edge 2nd
[EDGE2]/Edge 3rd [EDGE3]/Edge 4th
[EDGE4]/Peak[PEAK]*
Fixed
[FIXED]
Fixed value
[FIXED]
0.01 to 100.00%
(default value: 100%)
Start direction of count
measurement surfaces
[SUR, DIR]
Start direction
of count
measurement
surfaces
[SUR, DIR]
NEAR [NEAR]*/FAR[FAR]
Background
removal level
[NOISE]
Background
removal level
[NOISE]
0 to 1500
(default value: 300(ZW-8000
@
),
100(ZW-7000
@
/5000
@
))
Smoothing
size
[SMOOTH]
Smoothing
size
[SMOOTH]
1 pixel [1]/3 pixels [3]/5 pixels [5]*/7
pixels [7]/9 pixels [9]
Measurement
region
[REGION]
Area1
[REG.NO1]
Start position
[STR.POS]
-3750
μ
m to 3750
μ
m (default value
differs depending on Sensor Head).
End position
[END.POS]
-3750
μ
m to 3750
μ
m (default value
differs depending on Sensor Head).
Area2
[REG.NO2]
Start position
[STR.POS]
-3750
μ
m to 3750
μ
m (default value
differs depending on Sensor Head).
End position
[END.POS]
-3750
μ
m to 3750
μ
m (default value
differs depending on Sensor Head).
AreaTracks
[AREA.TR]
Follow mode
[MODE]
OFF[OFF]* / Start [START] /
End [END] / Start, End [ST ED]
Reference
edge
[REF.EDG]
Edge 1st [EDGE1]*/Edge 2nd
[EDGE2]/ Edge 3rd [EDGE3]/Edge
4th [EDGE4]/Peak [PEAK]
Following
edge
[FOL.EDG]
Edge 1st [EDGE1]/Edge 2nd
[EDGE2]*/Edge 3rd [EDGE3]/Edge
4th [EDGE4]/Peak [PEAK]
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......