Setting the Output Conditions
ZW-8000/7000/5000
User's Manual
171
4
Settin
gs for Function
Setting the Zero Reset Type
Set the zero reset type.
Multi View Explore
: [Bank Group] | [(Bank Data Name)] (double click)
→
Edit pane
: [Task Settings] icon (
)
→
Task Settings window : [Zero reset]
Item
Setting item
Setting value
Description
Zero reset
Type
Real value
Sets the measured value when a zero reset is executed to zero.
Hold value
Sets the measured value (hold value) when a zero reset is executed to zero.
This is enabled when hold measurement is performed.
1
Set [Status] to ON.
The zero reset type can be set only when [Status]
is set to ON.
2
Select the zero reset type from [Type].
The zero reset type can also be set by the operating keys on the Sensor Controller.
Setting the Zero Reset Mode p.258
Measurement of height
from reference surface
Zero reset
Reference A
Sensor head
Measurement of height
from reference surface
Zero reset
Hold A
(reference)
Direction of movement
Sensor head
Important
Note
Summary of Contents for ZW-7000 Series
Page 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Page 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Page 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Page 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Page 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Page 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Page 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Page 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Page 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Page 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Page 335: ......