3-5
ZUV
User’s Manual
Sect
ion 3
SETUP
Section 3
Setting the Irradiation Conditions
Setting Constant Irradiation Conditions
Irradiation power and time are set for the purpose of continually irradiating the UV light for
a certain time at a constant irradiation intensity.
■
Setting the irradiation power and time
Set the irradiation power and time in the LOCK mode top menu.
• For details on the settings, see Section 2, "Let's Try Irradiation".
• The irradiation power can also be adjusted in the irradiation power adjustment screen in the READY
mode.
■
Selecting preset time irradiation/unlimited irradiation
LOCK mode-[CH SET]-[1CH to 4CH]-[LIGNT TIME]
For details on the settings, see Section 2, "Let's Try Irradiation".
Setting value
Description
LIGNT
TIME
SETTING
(time setting)
Sets the irradiation time.
Enables the irradiation time set in the LOCK mode top screen.
UNLIMITED
(unlimited)
Performs irradiation with the irradiation time set to unlimited.
To stop irradiation, press the EMISSION button or the corresponding CH
button.
Irradiation power
(%)
Irradiation time (s)
Continuous
irradiation of UV light
for a certain time at
constant irradiation
power
Set the irradiation power and time.
Select preset time irradiation/unlimited irradiation.
Change to the RUN mode to irradiate with UV light.
Summary of Contents for ZUV Series
Page 1: ...Smart Curing System User s Manual Cat No Z281 E1 02 ZUV Series Mega Power Type...
Page 18: ...16 ZUV User s manual CONTENTS Introduction CONTENTS MEMO...
Page 44: ...2 18 Section 2 ZUV BASIC OPERATION ZUV User s Manual Section 2 Operating Modes MEMO...
Page 68: ...3 24 Section 3 SETUP ZUV User s Manual Section 3 Setting the System Environment MEMO...
Page 123: ...5 15 ZUV User s Manual Section 5 APPENDIX Section 5 INDEX MEMO...
Page 125: ......