in Fan Ionizers
Measurement Conditions
Installation distance: 300 mm
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 X 150 mm, 20 pF
Measurement Conditions
Airflow: Max.
Ionization time: ±1,000 V to ±100 V
Plate monitor: 150 X 150 mm, 20 pF
Conventional
ZJ-FA20
The airflow is dispersed,
lowering efficiency.
Engineering Data
The front louvers and
internal structure keep
the airflow uniform.
The newly developed airflow control system (AFCS) structure optimally controls the airflow of the fan
to efficiently carry the discharged ions to the target workpiece. This gives the ZJ-FA20 the highest
ionization performance in its class.
Even with the airflow at a low setting, ionization is completed in approximately 2 seconds. Small, light
workpieces are not blown away by the airflow, and static electricity is effectively neutralized.
A Unique Structure Provides a Uniform Airflow
Airflow Control System (AFCS)
High-speed Ionization
0
-300
-200
-100
0
100
ZJ-FA20
200
300
Distance direction
200
400
600
800
1 s
2 s
3 s
4 s
(mm)
(mm)
Ionization Area vs. Ionization Time
0
0.5
1
1.5
2
2.5
3
1.0
1.3
1.5
2.0
1.8
0.8
0.5
Adjustment
dial setting
Ionization time (s)
Airflow (m/s)
Airflow vs. Ionization Time
MIN:1
MAX: 5
2
3
4