background image

Model 

ZFX-XEQ

□□

Digital Equalizer

Please observe the following precautions to prevent failure to 
operate,malfunctions,or undesirable effests on product performance.

1. Do not install the product in locations subjected to the following conditions:

 Ambient temperature outside the rating

 Rapid temperature fluctuations (causing condensation)

 Relative humidity outside the range of 35 to 85%

 Presence of corrosive or flammable gases

 Presence of dust, salt, or iron particles

 Direct vibration or shock

 Direct sunlight or near heaters

 Water, oil, or chemical fumes or spray

 Strong magnetic or electric field

2. Do not install the product in locations subjected to the following conditions

 Before connecting/disconnecting the connectors,make sure that the Amplifier 

Unit is turned OFF. The Extension Cable may break down if it is connected or   
disconnected while the power is ON. 

 Tighter mounting screws at the torque specified. 

Recommended screw tightening torque : 0.15N

m

 Fasten the connector connections of this product before use to prevent this 

product from moving.

 The length of a total cable is made within 28.4m between Controller and Camera.

 Please do not use it for ZFX-XEQ

□□

 excluding a special extension 

cable(ZFX-XC

□□

BR). 

3. Cleaning

 Do not use paint thinner, benzene, acetone, or kerosene for cleaning. 

PRECAUTIONS ON SAFETY

OMRON Corporation

Suitability for Use

EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0  Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS  LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.
Phone:1-847-843-7900  Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05-08(Lobby 2),
Alexandra Technopark, Singapore 119967 
Phone : 65-6835-3011  Fax :65-6835-2711

o

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product. 
 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

CHINA
OMRON(CHINA) CO., LTD. 
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road, 
PuDong New Area, Shanghai, 200120, China
Phone : 86-21-5037-2222  Fax :86-21-5037-2200

O C T,   2 0 0 9

PRECAUTIONS FOR SAFE USE

PRECAUTIONS FOR CORRECT USE

Meanings of Signal Words

Meaning of Alert Symbols

[UNIT:mm]

1. Installation Environment
Please observe the following precautions to prevent failure to operate, 
malfunctions, or undesirable effects for safe use of the products

 Do not use the product in environments where it can be exposed to 

inflammable/explosive gas.

 To secure the safety of operation and maintenance, do not install the product 

close to high-voltage devices and power devices.

2. Power Supply and Wiring

 High-voltage lines and power lines must be wired separately from this product. 

Wiring them together or placing them in the same duct may cause induction, 
resulting in malfunction or damage.

 Please connect it with a special device(Sensor Head, Controller). 

Indicates a potentially hazardous situation which, 

if not avoided,will result in minor or moderate injury, 

or may result in serious injury or death. 

Additionally there may be significant property damage.

WARNING

This product is not designed or rated for ensuring safety 

of  persons. Do not use it for such purpose.

Do not touch the terminals while the power is ON.

theimay cause an electric shock.

Do not disassemble or touch the interior while the power 

is ON. this may cause an electric shock.

WARNING

3. Others

 Do not attempt to dismantle, repair, or modify the product.

 Please do not use ZFX for the safety circuit such as devices related to nuclear 

power and life.

 Dispose of this product as industrial waste.

 If you suspect an error or malfunction, stop using the controller immediately, turn 

off the power supply, and consult your OMRON representative.

Connection method

Please connect it as shown in the figure below when you connect ZFX-XEQ

□□

 and ZFX-XC

BR with ZFX-S Series and ZFX-C Series.

ZFX-SR

□□□ 

or

 

ZFX-SC

□□□

ZFX-S/SC

ZFX-SR

□□□

or

 

ZFX-SC

□□□ 

ZFX-XEQ01

ZFX-XEQ02

ZFX-C

□□□ 

ZFX-XC

□□

BR

ZFX-XEQ01

ZFX-XEQ02

ZFX-C

□□□ 

ZFX-XC

□□

BR

ZFX-VS(R) 3m

ZFX-S/SC

Dimension

28

12.6 Dia.

28±0.1

3

1

8

36

28

24.2

26.2

ZFX-XEQ01

ZFX-XEQ02

MOUNTING SCREW HOLES

MOUNTING HOLES

MOUNTING HOLES

2-

3

26PIN (FEMALE)

28±0.1

2-3.5 Dia.

VINYL INSULATED ROUND 6.1 Dia. 15 CORES

13

75

36

45.9

200

43

2-M3

VINYL INSULATED ROUND 6.1 Dia. 15 CORES

2-3.5 Dia.

75

45.9

200

25.34

5.9

38.14

+30
   0

+30
   0

MOUNTING SCREW HOLES

26PIN (FEMALE)

26PIN (MALE)

20PIN (FEMALE)

Specifications

Item
Applicable controller

Applicable 
Vibration resistance

Shock resistance

Weight

Ambient temperature

Ambient humidity

Ambient environment

Degree of protection

Connection method

Connected position

Approx.60

Camera side

Double-end connector

IE60529 IP20

No corrosive gases

Operating and Storage:35 to 85

RH 

Operating

0 to 

+

50

, Storage:

-

25 to 

+

65

(with no icing or condensation)

150m/s, 3 times each in 6 directions

ZFX-S Serise

10

150Hz ; half-amplitude:0.35mm 

(Acceleration:max. 50m/s  ) 

10 times each X,Y and Z directions for 8min

ZFX-C Serise

ZFX-XEQ01

ZFX-XEQ02 

Cable length

0.2m

Material

Case:Polycarbonate (PC)

Minimum bend radius

40mm

Controller side

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet pri-

marily describes precautions required in installing and

operating the product.

Before operating the product, read the sheet thoroughly to

acquire sufficient knowledge of the product. For your con-

venience, keep the sheet at your disposal.

© 

OMRON Corporation 2008 All Rights Reserved.

The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio 
interference, in which case the user may be required to take adequate
measures to reduce interference.

2

Manufacturer:
  Omron Corporation,
  Shiokoji Horikawa, Shimogyo-ku,
  Kyoto 600-8530 JAPAN
  Ayabe Factory
  3-2 Narutani, Nakayama-cho,
  Ayabe-shi, Kyoto 623-0105 JAPAN

TRACEABILITY INFORMATION:
Representative in EU:
  Omron Europe B.V.
  Wegalaan 67-69
  2132 JD Hoofddorp,
  The Netherlands

Reviews: