Model
ZFX-XEQ
□□
Digital Equalizer
Please observe the following precautions to prevent failure to
operate,malfunctions,or undesirable effests on product performance.
1. Do not install the product in locations subjected to the following conditions:
・
Ambient temperature outside the rating
・
Rapid temperature fluctuations (causing condensation)
・
Relative humidity outside the range of 35 to 85%
・
Presence of corrosive or flammable gases
・
Presence of dust, salt, or iron particles
・
Direct vibration or shock
・
Direct sunlight or near heaters
・
Water, oil, or chemical fumes or spray
・
Strong magnetic or electric field
2. Do not install the product in locations subjected to the following conditions
・
Before connecting/disconnecting the connectors,make sure that the Amplifier
Unit is turned OFF. The Extension Cable may break down if it is connected or
disconnected while the power is ON.
・
Tighter mounting screws at the torque specified.
Recommended screw tightening torque : 0.15N
・
m
・
Fasten the connector connections of this product before use to prevent this
product from moving.
・
The length of a total cable is made within 28.4m between Controller and Camera.
・
Please do not use it for ZFX-XEQ
□□
excluding a special extension
cable(ZFX-XC
□□
BR).
3. Cleaning
・
Do not use paint thinner, benzene, acetone, or kerosene for cleaning.
PRECAUTIONS ON SAFETY
OMRON Corporation
Suitability for Use
EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0 Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.
Phone:1-847-843-7900 Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05-08(Lobby 2),
Alexandra Technopark, Singapore 119967
Phone : 65-6835-3011 Fax :65-6835-2711
o
THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or
regulations that apply to the combination of the products in the customer's
application or use of the product.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
CHINA
OMRON(CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Phone : 86-21-5037-2222 Fax :86-21-5037-2200
O C T, 2 0 0 9
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
●
Meanings of Signal Words
●
Meaning of Alert Symbols
[UNIT:mm]
1. Installation Environment
Please observe the following precautions to prevent failure to operate,
malfunctions, or undesirable effects for safe use of the products
・
Do not use the product in environments where it can be exposed to
inflammable/explosive gas.
・
To secure the safety of operation and maintenance, do not install the product
close to high-voltage devices and power devices.
2. Power Supply and Wiring
・
High-voltage lines and power lines must be wired separately from this product.
Wiring them together or placing them in the same duct may cause induction,
resulting in malfunction or damage.
・
Please connect it with a special device(Sensor Head, Controller).
Indicates a potentially hazardous situation which,
if not avoided,will result in minor or moderate injury,
or may result in serious injury or death.
Additionally there may be significant property damage.
WARNING
This product is not designed or rated for ensuring safety
of persons. Do not use it for such purpose.
Do not touch the terminals while the power is ON.
theimay cause an electric shock.
Do not disassemble or touch the interior while the power
is ON. this may cause an electric shock.
WARNING
3. Others
・
Do not attempt to dismantle, repair, or modify the product.
・
Please do not use ZFX for the safety circuit such as devices related to nuclear
power and life.
・
Dispose of this product as industrial waste.
・
If you suspect an error or malfunction, stop using the controller immediately, turn
off the power supply, and consult your OMRON representative.
■
Connection method
Please connect it as shown in the figure below when you connect ZFX-XEQ
□□
and ZFX-XC
□
BR with ZFX-S Series and ZFX-C Series.
・
ZFX-SR
□□□
or
ZFX-SC
□□□
・
ZFX-S/SC
ZFX-SR
□□□
or
ZFX-SC
□□□
ZFX-XEQ01
ZFX-XEQ02
ZFX-C
□□□
ZFX-XC
□□
BR
ZFX-XEQ01
ZFX-XEQ02
ZFX-C
□□□
ZFX-XC
□□
BR
ZFX-VS(R) 3m
ZFX-S/SC
■
Dimension
28
12.6 Dia.
28±0.1
3
1
8
36
28
24.2
26.2
・
ZFX-XEQ01
・
ZFX-XEQ02
MOUNTING SCREW HOLES
MOUNTING HOLES
MOUNTING HOLES
2-
M
3
26PIN (FEMALE)
28±0.1
2-3.5 Dia.
VINYL INSULATED ROUND 6.1 Dia. 15 CORES
13
75
36
45.9
200
43
2-M3
VINYL INSULATED ROUND 6.1 Dia. 15 CORES
2-3.5 Dia.
75
45.9
200
25.34
5.9
38.14
+30
0
+30
0
MOUNTING SCREW HOLES
26PIN (FEMALE)
26PIN (MALE)
20PIN (FEMALE)
■
Specifications
Item
Applicable controller
Applicable
Vibration resistance
Shock resistance
Weight
Ambient temperature
Ambient humidity
Ambient environment
Degree of protection
Connection method
Connected position
Approx.60
g
Camera side
Double-end connector
IE60529 IP20
No corrosive gases
Operating and Storage:35 to 85
%
RH
Operating
:
0 to
+
50
℃
, Storage:
-
25 to
+
65
℃
(with no icing or condensation)
150m/s, 3 times each in 6 directions
ZFX-S Serise
10
〜
150Hz ; half-amplitude:0.35mm
(Acceleration:max. 50m/s )
10 times each X,Y and Z directions for 8min
ZFX-C Serise
ZFX-XEQ01
ZFX-XEQ02
Cable length
0.2m
Material
Case:Polycarbonate (PC)
Minimum bend radius
40mm
Controller side
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
©
OMRON Corporation 2008 All Rights Reserved.
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
2
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
Ayabe Factory
3-2 Narutani, Nakayama-cho,
Ayabe-shi, Kyoto 623-0105 JAPAN
TRACEABILITY INFORMATION:
Representative in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands