![background image](http://html.mh-extra.com/html/omron/zfx-sr10-1/zfx-sr10-1_instruction-sheet_1633359002.webp)
(1) Lighting part
This section emits light.
(2) Receiver part
This section captures the
image.
(3) Connector
This connector is connected
to the Amplifier Unit.
(4) Sensor Head mounting fixture
This fixture is for mounting the Sensor Head.
This fixture can be mounted on all of the four
mounting surfaces.
(5) Focus adjustment control
This control is used for adjusting the focus of the image.
(6) Ventilation film
This film prevents the front panel from condensation.
The following graphs show the relationship between detection range and setting
distance for each model of Sensor Head.
Values differ according to each model of Sensor Head, so fully check the model before
using these graphs.
(Example)
When using a ZFX-SR10-1 Sensor Head at
a detection range of 7 mm required for
the location of the sensing object, the setting
distance of Sensor Head becomes 40mm.
Detection range
H (mm)
Setting distance
L (mm)
Attach the mounting fixture (provided with the
Smart Sensor) to the side of the Sensor Head.
The mounting fixture can be installed on all of the
four mounting surfaces.
Insert a regular screwdriver into the gap (one of
the two gaps) between the mounting
fixture and the Sensor Head case, and remove the
mounting fixture.
Attach the ferrite core (provided with the Smart Sensor) to the connector side of the
Sensor Head.
(1) Align the two hooks on one side of the mounting
fixture with the two grooves on the Sensor Head
body (light emitting side).
(2) Press in the other hook.
Push down until you hear it snap into place.
(3) Make sure that the mounting fixture is firmly
fixed on the Sensor Head.
Mounting
fixture
Hook
(1) Install the Sensor Head at the installation distance obtained in the above graphs.
(2) Turn the focus adjustment control
to the left and right to adjust the focus.
Focus
adjustment
control
Before turning the focus adjustment control slightly to the left and right, make sure that the
guide light is not at the upper or lower limit positions. The focus adjustment control is a
multi-turn variable resistor. However, the control stops turning at the upper or lower limit
positions. Do not exert unnecessary force to turn the control at the upper or lower limit
positions as this might damage the control.
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Please observe the following precautions to prevent failure to operate, malfunctions, or
undesirable effects on product performance.
Do not install the product in locations subjected to the following conditions.
・
Ambient temperature outside the rating
・
Rapid temperature fluctuations (causing condensation)
・
Relative humidity outside the range of 35 to 85%
・
Presence of corrosive or flammable gases
・
Presence of dust, salt, or iron particles
・
Direct vibration or shock
・
Reflection of intense light (such as other laser beams,electric arc welding
machines or ultraviolet rays)
・
Direct sunlight or near heaters
・
Water, oil, or chemical fumes or spray
・
Strong magnetic or electric field
(1) Installation Site
The center of the optical axis sometimes differs according to each Sensor Head.
During installation, be sure to check the center of the image and the detection
range on theLCD monitor of the Amplifier Unit.
The center of the guide light and detection range are for reference only.
(3) Optical Axis and Detection Range
Please observe the following precautions for safe use of the products.
・
Do not use thinner, benzene, acetone or kerosene to clean the Sensor Head and
Amplifier Unit.
・
If large dust particles adhere to the front Panel of the Sensor Head, use a blower
brush (used to clean camera lenses) to blow them off. Do not blow off the dust
particles with your mouth.
・
To remove smaller dust particles, wipe gently with a soft cloth. Do not use
excessive force to wipe off dust particles. Scratches on the front Panel may cause
errors.
(6) Maintenance and Inspection
(5) Focus adjustment
control
(6) Ventilation film
49mm
34mm
4.9mm
8.9mm
Setting
distance
(L)
Detection
range
(H)
Workpiece
Detection range H
Setting
distance L
(2) Receiver part
(3) Connector
(4) Sensor Head
mounting fixture
(1) Lighting part
Mounting
fixture
(1) Installation Environment
・
Do not use the product in environments where it can be exposed to inflammable /
explosive gas.
・
To secure the safety of operation and maintenance, do not install the product close
to high-voltage devices and power devices.
・
During installation, make sure that screws are tightened firmly.
(3) Others
・
Do not attempt to dismantle, repair, or modify the product.
・
Dispose of this product as industrial waste.
・
If abnormal odors, heating, or smoke occurs, stop using the Smart Sensor
immediately, turn OFF the power, and consult with your OMRON representative.
(2) Power Supply and Wiring
・
High-voltage lines and power lines must be wired separately from this product.
Wiring them together or placing them in the same duct may cause induction,
resulting in malfunction or damage.
(2) Power Supply and Wiring
・
Do not peel off or probe the ventilation film with a sharp-pointed object. If you
so, the specifications of the protective structure may no longer be satisfied.
・
Do not block the ventilation film. Doing so might cause the front panel to be
con-densed.
(4) Ventilation Film
Part Names and Functions
Attaching the ferrite core
Installing the mounting fixture
Removal procedure
Installation distance
Installation procedure
Specitications
Dimensions
Model
ZFX-SR10-1
Smart Sensor
For Model ZFX-C
□□
Sensor head unit
・
Before connecting/disconnecting the Sensor Head, make sure that the Smart
Sensor is turned OFF. The Smart Sensor may break down if the Sensor Head is
connected or disconnected while the power is ON.
・
Use only combinations of Sensor Heads and Sensor Controllers specified in this
sheet.
ZFX-SR10-1
(Narrow View)
Setting distance (L)
Detection range (H V)
Relation between setting
distance and detection range
Guide light
Object lighting method
Object light source
Sensing element
Shutter
Power supply voltage
Current consumption
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Ambient temperature
Ambient humidity
Ambient atmosphere
Connection method
34 to 49 mm
4.9×4.9 mm to 8.9×8.9 mm
Not available
Pulse lighting
Eight red LEDs
1/3-inch interline color CCD (reading all pixels)
Electronic shutter, shutter time: 1/170 to 1/20,000s
15 VDC (Supplied from Amplifier Unit.)
Approx. 200 mA
1,000 VAC, 50/60 Hz for 1 min
10 to 150 Hz, 0.35-mm single amplitude, 10 times each in X, Y, and Z directions for 8 min
150 m/s 2 , three times each in six directions (up/down, left/right, forward/backward)
Operating: 0 to 40 ℃, Storage: -20 to 65 ℃ (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
Must be free of corrosive gas.
Detection
range
V
H
Ferrite core
© OMRON Corporation
2008-2009
All Rights Reserved.
67.9
17.9
5.6
CONNECTOR
26.2
38.14
25.34
5.9
24.2
HEAT-RESISTANT VINYL CHLORIDE SHIELD CORD
5.8 Dia. STANDARD LENGTH 2m
NOTE 1.
8
34
17.9
FOCUS ADJUSTMENT VOLUME
30
(
6.36
)
(
6.36
)
30
4
33.6
32
4.5
4.5
4.5
4.5
23.3
32
2-M4 DEPTH 6
1/4-20UNC
DEPTH 6
34
20
33.6
20±0.1
2-4.5Dia.
MOUNTING SCREW HOLES
(unit : mm)
NOTE 1. ATTACHEMENT ON EACH SIDE IS POSSIBLE FOR MOUNTING BRACKET
ZFX-SR10-1
(5) Focus Adjustment Control
・
Do not exert the torque of 5N
・
m or more as this might damage the control.
Tighter mounting screws at the torque specified.
Recommended screw tightening torque
M4:1.2N
・
m, 1/4”-20UNC:2.6N
・
m
(7) Installation Precautions
NOTICE:
This product meets CISPR11 class A . The intended use of this product is in an
industrial environment only.
Item
Prewired, Standard cable (length: 2 m)
Degree of protection
Materials
Weight
Accessories
IEC60529, IP65
Case: ABS, Mounting bracket: PBT
Approx. 200 g (including mounting bracket and cord)
Mounting bracket (1), Ferrite core (2), Instruction sheet
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
Ayabe Factory
3-2 Narutani, Nakayama-cho,
Ayabe-shi, Kyoto 623-0105 JAPAN
TRACEABILITY INFORMATION:
Representative in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
OMRON Corporation
Suitability for Use
EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0 Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.
Phone:1-847-843-7900 Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05-08(Lobby 2),
Alexandra Technopark, Singapore 119967
Phone : 65-6835-3011 Fax :65-6835-2711
o
THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or
regulations that apply to the combination of the products in the customer's
application or use of the product.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
CHINA
OMRON(CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Phone : 86-21-5037-2222 Fax :86-21-5037-2200
OCT, 2009