Indicates a potentially hazardous situation which, if not avoided, will
result in minor or moderate injury, or may result in serious injury or
death. Additionally there may be significant property damage.
This product is not designed or rated for ensuring safety
of persons. Do not use it for such purposes.
Meaning of Alert Symbols
Alert statements
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.
Model
ZFX-S/-SC
DIGITAL CAMERA FOR
Model ZFX-C
̲̲
(1) The camera base attached to the bottom of the camera can also
be attached to the another side of the camera,Remove the
three screws(M2×6) from the base and re-attach the base to
the another side of the camera.(Recommended screw
tightening torque
:
0.14N
・
m)
Pixel size
Shutter speed
Image rate function
Frame rate (at capture of
entire screen)
Lens mounting
Item
ZFX-S
WARNING
WARNING
PRECAUTIONS ON SAFETY
659(H)
×
494(V)
7.4
μ
m(H)
×
7.4
μ
m(V)
Not available
90 fps
C mount
■
Specifications
■
Changing the Camera Base Mount Position
(1) Using the Camera cable ZFX-VS
□
(sold separately), make a
connection between the camera's Camera cable connector and
the controller's camera connector.
■
Connecting
■
Dimensions
© OMRON Corporation
2007
All Rights Reserved.
(
Unit
:
mm
)
ZFX-SC
All-pixel capture inter-line
transfer type 1/3” CCD
(monochrome)
Partical function (partial capture)
Image capture
element
Effective number of
pixels
1/170 to 1/20000 (sec)
1/2 partial,1/4 partial
Fine,Normal,High speed
Not available
All-pixel capture inter-line
transfer type 1/3” CCD
(color)
54.5
(6.3)
18
11
40.5
8.5
45.5
2x3-M2 DEPTH 3
25.5
11
29
31
(15.5)
28
1"-32UN-2A(C MOUNT)
(14.5)
18
11
40.5
3-M2 DEPTH 3
28Dia
8
46.5
(4.8)
(8.8 Dia)
(18.85)
(29.5)
31.3±2
1/4"-20UNC DEPTH 8
21.3±2
2-M4
DEPTH
8
VINYL INSULATED ROUND CORD
6.1Dia. 15CORES
NAME PLATE
20±0.1
PRECAUTIONS FOR SAFE USE
PRECAUTIONS FOR CORRECT USE
Please observe the following precautions to prevent failure to operate,
malfunctions, or undesirable effects on product performance.
Do not install the product in locations subjected to the following
conditions:
・
Ambient temperature outside the rating
・
Rapid temperature fluctuations (causing condensation)
・
Relative humidity outside the range of 35 to 85%
・
Presence of corrosive or flammable gases
・
Presence of dust, salt, or iron particles
・
Direct vibration or shock
・
Reflection of intense light (such as other laser beams , electric arc
welding machines or ultraviolet rays)
・
Direct sunlight or near heaters
・
Water, oil, or chemical fumes or spray
・
Strong magnetic or electric field
(1) Installation Site
Please observe the following precautions for safe use of the products.
(1) Installation Environment
・
Do not use the product in environments where it can be exposed to
inflammable / explosive gas.
・
To secure the safety of operation and maintenance, do not install the
product close to high-voltage devices and power devices.
・
During installation, make sure that screws are tightened firmly.
(3) Others
・
Do not attempt to dismantle, repair, or modify the product.
・
Dispose of this product as industrial waste.
・
If abnormal odors, heating, or smoke occurs, stop using the Smart
Sensor immediately, turn OFF the power, and consult with your
OMRON representative.
・
Never use this product for safety device used in nuclear power
facilitics or those used for the protection of human life.
(2) Power Supply and Wiring
・
High-voltage lines and power lines must be wired separately from this
product. Wiring them together or placing them in the same duct may
cause induction, resulting in malfunction or damage.
(2) Power Supply and Wiring
・
Do not use unspecified camera cable and a strobe controller other
than those that specified in this manual. Connection with
unspecified camera cable and/or strobe controller may cause the
malfunction and damage at the worst case.
・
Before connecting/disconnecting the Camera, make sure that the
Smart Sensor is turned OFF. The Smart Sensor may break down if
the Camera is connected or disconnected while the power is ON.
・
Use only combinations of Camera and Controllers specified in this
sheet.
・
Do not remove the base attached to the Camera.
The center of the optical axis varies with the camera used.
Therefore, when installing the camera, always check the center of the
image displayed on the monitor.
(3) Optical axis of the Camera.
・
Do not use thinner, benzene, acetone or kerosene to clean the
Sensor Head and Amplifier Unit.
・
If large dust particles adhere to the Camera, use a blower brush
(used to clean camera lenses) to blow them off. Do not blow off the
dust particles with your mouth.
・
To remove smaller dust particles, wipe gently with a soft cloth.
Do not use excessive force to wipe off dust particles. Scratches on
the front Panel may cause errors.
(4) Maintenance and Inspection
If you do not use the lighting connector on the back of the camera,
do not remove the cap that is attached to the connector.
(5) The cap of the lighting connector
(6) Installation Precautions
Tighter mounting screws at the torque specified.
Recommended screw tightening torque
M4:1.2N
・
m,
1/4”-20UNC:2.6N
・
m
■
Part Names and Functions
(
1
)
(
2
)
(
3
)
Name
(1)Lighting connector
(2)Camera cable connector
(3)Camera mounting base
*1 Do not remove the base from the Camera.
Description
This connector is used to connect an external
lighting(Strobe Controller).
This connector is used for connecting to the
Controller via a camera cable(ZFX-VS/VSR).
This camera’s mounting base is fastened with
screws to hold the camera in place. The camera’s
mounting base can be installed on all of the four
mounting surfaces. (*1)
Connectable controller
Lighting
Rahtings
Optional lighting I/F
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Ambient environment
Available
External lighting : 3Z4S-LT *1
Flash Controller : made by Moritex Corporation
3Z4S-LT MLEK-C100E1TSX *1
15VDC (supplied from Controller)
Approx. 160mA
Operating : 0 to +50
℃,
Storage : -25 to +65
℃
(with no icing or condensation)
Operating and storage : 35 to 85% (with no condensation)
No condensation gases allowed
Degree of protection
Dielectric strength
Vibration resistance
IP20 (IEC60529)
500VAC 50Hz/60Hz 1min
10 to 150Hz : half-amplitude 0.35mm
(maximum acceleration : 50m/s
2
)
10 times for 8 minutes each in X,Y and Z directions
150m/s
2
3 times each in 6 directions
(up/down, left/right, foward/backward)
Shock resistance
Connection method
Materials
Weight
Connector connection type
(camera cable ZFX-VS/VSR required)
Case : Aluminum die cast alloy (C mount section),
zinc die cast alloy (mounting base side),
Cover : Zinc-plated copper plate 0.5mm thich
Camera mounting base : ABS
Approx. 80g
ZFX-C__
Accessories
Instruction sheet
*1: 3Z4S-LT are not yet released for overseas.
*2: Regulations and Standards
This product is compliant with the standards below:
EN Standards(European Standards), EN61326-1
Electromagnetic environment : Industrial electromagnetic environment
(EN/IEC 61326-1 Table 2)
Also, the following condition is applied to the immunity test of this product.
: If the level of disturbance of the video is that with
characters on the monitor are readable, the test is pass.
NOTICE:
This product meets CISPR11 class A. The intended use of this product
is in an industrial environment only.
Manufacturer:
Omron Corporation,
Shiokoji Horikawa, Shimogyo-ku,
Kyoto 600-8530 JAPAN
TRACEABILITY INFORMATION:
Importer in EU :
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters