background image

Enclosed Switches

 

ZE/ZV/XE/XV

F-121

Lim

it 

Switch

es

Ratings

Note: 1.

The above figures are for standard currents.

2.

Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).

3.

Lamp load has an inrush current of 10 times the steady-state current.

4.

Motor load has an inrush current of 6 times the steady-state current.

Characteristics

Note: 1.

The above figures are initial values.

2.

IP65 for 

@

E-N models and IP60 for 

@

E-Q models.

3.

The values are calculated at an operating temperature of 5

°

C to 35

°

C, and an operating humidity of 40% to 70%. Contact your OMRON

sales representative for more detailed information on other operating environments.

4.

At the operation limit positions.

5.

Only for plunger, sealed plunger, roller arm lever, and sealed roller arm lever.

6.

Only for crossroller plunger, sealed crossroller plunger, roller plunger, and sealed roller plunger.

Contact

Contact

Rated voltage

Non-inductive load

Inductive load

Resistive load

Lamp load

Inductive load

Motor load

NC

NO

NC

NO

NC

NO

NC

NO

ZE-

@

ZV-

@

ZV2-

@

125 VAC

15 A

3 A

1.5 A

15 A

5 A

2.5 A

250 VAC

15 A

2.5 A

1.25 A

15 A

3 A

1.5 A

480 VAC

10 A

1.5 A

0.75 A

6 A

1.5 A

0.75 A

125 VDC

0.5 A

0.5 A

0.05 A

0.05 A

250 VDC

0.25 A

0.25 A

0.03 A

0.03 A

XE-

@

XV-

@

XV2-

@

8 VDC

15 A

3 A

3 A

15 A

15 A

10 A

10 A

14 VDC

15 A

3 A

3 A

15 A

10 A

10 A

10 A

30 VDC

15 A

3 A

3 A

10 A

10 A

10 A

6 A

125 VDC

10 A

3 A

1.5 A

7.5 A

6 A

6 A

4 A

250 VDC

3 A

1.5 A

0.75 A

2 A

1.5 A

2 A

1 A

Inrush current

NC

30 A max.

NO

15 A max.

Degree of protection

IP65 (see note 2)

Durability (see note 3)

Mechanical:
Z

@

: 10,000,000 operations min.

X

@

: 1,000,000 operations min.

Electrical:
Z

@

: 500,000 operations min., for 15 A, 250 VAC resistive load

X

@

: 100,000 operations min., for 10 A, 125 VDC resistive load

Operating speed

Plunger type:  0.01 mm to 0.5 m/s
Lever type: 

0.02 mm to 0.5 m/s

Operating frequency

Mechanical: 120 operations/min
Electrical:

20 operations/min

Rated frequency

50/60 Hz

Insulation resistance

100 M

 min. (at 500 VDC)

Contact resistance

15 m

 max. (initial value)

Terminal temperature rise

50

°

 max.

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
2,000 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each 
terminal and non-current-carrying metal part (1,500 VAC for Z

@

 models and X

@

 models)

Vibration resistance

Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 4)

Shock resistance (see note 4)

Destruction: 1,000 m/s

2

 min.

Malfunction: 100 m/s

2

 min. (see note 5), 50 m/s

2

 min. (see note 6)

Ambient temperature (see note 1)

Operating: –10

°

C to 80

°

C (with no icing)

Ambient humidity

Operating: General-purpose type: 85% max.

Sealed type:

95% max.

Weight

Approx. 260 to 280 g

Summary of Contents for XE -

Page 1: ...unting Direction E Side mounting V Base mounting V2 Diagonal side mounting 3 Actuator Q Plunger Q22 Roller plunger Q21 Crossroller plunger QA2 Roller arm lever QA277 One way action roller arm lever N...

Page 2: ...load SPDT Plunger ZE Q 2 ZE N 2 ZV2 Q 2 ZV2 N 2 ZV Q 2 ZV N 2 Roller plunger ZE Q22 2 ZE N22 2 ZV2 Q22 2 ZV2 N22 2 ZV Q22 2 ZV N22 2 Crossroller plung er ZE Q21 2 ZE N21 2 ZV2 Q21 2 ZV2 N21 2 ZV Q21...

Page 3: ...2 8 VDC 15 A 3 A 3 A 15 A 15 A 10 A 10 A 14 VDC 15 A 3 A 3 A 15 A 10 A 10 A 10 A 30 VDC 15 A 3 A 3 A 10 A 10 A 10 A 6 A 125 VDC 10 A 3 A 1 5 A 7 5 A 6 A 6 A 4 A 250 VDC 3 A 1 5 A 0 75 A 2 A 1 5 A 2 A...

Page 4: ...4 mm 3 5 mm 6 mm 5 5 mm 6 mm MD max 0 47 mm 0 12 mm 0 4 mm 0 72 mm 0 4 mm OP 45 8 0 8 mm 49 7 0 8 mm Model XE NA277 2 ZV 2 Q 2 XV 2 Q 2 ZV 2 Q22 2 XV 2 Q22 2 OF 7 26 N 2 45 to 3 43 N 5 00 N max 2 45...

Page 5: ...4 operations Durability x 10 4 operations Durability x 10 4 operations Operating frequency 20 operations min OT Full stroke Operating frequency 20 operations min OT Full stroke Operating frequency 20...

Page 6: ...duit opening Case Tightening band Rubber cap CR 19 25 5 24 86 23 17 25 4 0 12 2 1 0 1 25 4 0 3 25 4 0 3 19 25 5 24 86 23 17 25 4 0 12 2 1 0 1 25 4 0 3 19 25 5 24 86 23 17 25 4 0 12 2 1 0 1 Plunger ZE...

Page 7: ...1 JIS B0202 G1 2 Effective thread 4 threads min One way Action Roller Arm Lever ZE QA277 2 XE QA277 2 18 7 dia 9 see note 1 Operate in this direction only JIS B0202 G1 2 Effective thread 4 threads mi...

Page 8: ...nless steel roller 2 Adjustable between 0 and 225 One way Action Sealed Roller Arm Lever ZE NA277 2 XE NA277 2 See note 2 17 4R JIS B0202 G1 2 Effective thread 4 threads min Operates in this direction...

Page 9: ...0 5 0 3 3 25 4 0 3 23 17 86 23 1 max 39 7 30 0 8 69 5 0 8 19 3 PT 12 7 dia 4 8 see note 1 Note 1 Stainless steel roller 2 Only the ZV2 Q21 2 and XV2 Q21 2 incorporate mounting holes 3 OP for ZV2 Q21 2...

Page 10: ...threads min Operates in this direction only PT Two 4 3 0 2 dia holes OP see note 3 OP see note 4 0 Two 5 4 0 2 dia holes see note 2 JIS B0202 G1 2 Effective thread 4 threads min 12CR see note 1 53R N...

Page 11: ...Stainless steel roller 2 Adjustment between 0 to 225 3 Only the ZV2 NA2 2 and XV2 NA2 2 incorporate mounting holes Sealed Roller Arm Lever ZV 2 NA2 2 XV 2 NA2 2 Two 4 3 0 2 dia See note 2 t 3 ZV NA2 2...

Page 12: ...lies to side mounting or bottom mounting M4 screws for head 2 This torque range applies to side diagonal mounting M5 Allen head bolt Mounting Mounting Holes Operation Operating method shape of cam or...

Reviews: