![background image](http://html1.mh-extra.com/html/omron/v680-ha63/v680-ha63_instruction-sheet_741388002.webp)
(See note 1.)
40
Mounting hook
Spacers
DIN Track
End Plate
10 mm min.
(See note 2.)
Specifications
Mounting to DIN Track
1. Installation Location
Do not install the product in the following locations:
・
Locations subject to corrosive gases, dust, dirt, metal powder, or salt
・
Locations where the specified ambient operating temperature range is
exceeded
・
Locations subject to extreme temperature changes that may result in
condensation
・
Locations where the specified ambient operating humidity range is
exceeded
・
Locations subject to contact with water, oil, or chemicals
2.Installation
・
The product uses the 13.56MHz frequency band to communicate
with Tags. Some devices, such as some motors, inverters, and
switch mode power supplies, generate electromagnetic waves
(i.e., noise) that can affect communications with the Tags. If any
of these devices are nearby, communications with Tags may be
affected or Tags may be destroyed. If the product is to be used
near such devices, check the effects on communications before
using the product.
・
To minimize the general influence of noise, follow the following
precautions:
(1) Ground the earth terminal of this product and any metallic
material located around the product to 100
Ω
or less.
(2) Keep product wiring away from high voltage or heavy
current.
・
The product does not provide a water-proof structure. Do not use
it where mists are present.
・
Do not use chemicals that will affect product materials.
3.Storage
Do not store the product in the following locations.
・
Locations subject to corrosive gases, dust, dirt, metal powder, or
salt
・
Locations where the specified ambient storage temperature
range is exceeded
・
Locations subject to extreme temperature changes that may
result in condensation
・
Locations where the specified ambient storage humidity range is
exceeded
・
Locations subject to contact with water, oil, or chemical
4.Cleaning
・
Do not use thinners for cleaning. Resin materials and the case
coating will be dissolved by thinners,benzenes,acetones and
kerosenes.
Names of parts
General Specifications
Item
Specifications
13.56MHz
Performance Specifications
Ambient operating humidity
Ambient operating temperature
Oscillating frequency
35 to 85%RH(no condensation)
-10 to +55ºC (no freezing)
Item
Specifications
Weight
Enclosure rating
Shock resistance
Vibration resistance
Dielectric strengh
Insulation resistance
About 850g(At 10m cable)
IEC60529 IP40
(When V680-HS63-R or V680-HS52-R
is connected)
Durable at 500m/s
2
, 3 times
In 6 directions
Durable at 10 to 500Hz
Double amplitude less than 1.5mm
10 sweeps for 11 minutes each in 3 directions
By applying 1000VAC, 50/60 Hz power
for 1minute between cable terminal
and casing
Dimension
ID System Amplifier
Model
V680-HA63
□
Operation Indicator
13.7
65
18
51
36
40
25
25
3.5
15
35.6
25
Vinyl-insulated round cable,5.8 mm dia. Standard length: 5 m
Connector
RUN
COMM
NORM
ERR
LV6/7D
LV5/7A
LV4/76
LV3/72
LV2/71
LV1/70
when the power is turned ON
A command has been received from the host device.
Communications with the Tag have completed normally.
A communications error with the Tag has occurred.
Maintenance mode
:
It lights in the distance/speed level 6.
RUN mode
:
When Write-protection error, it lights.
Maintenance mode
:
It lights by distance/speed level 5 or more.
RUN mode
:
When Address error, it lights.
Maintenance mode
:
It lights by distance/speed level 4 or more.
RUN mode
:
When Memory error, it lights.
Maintenance mode
:
It lights by distance/speed level 3 or more.
RUN mode
:
When Tag non-existent error, it lights.
Maintenance mode
:
It lights by distance/speed level 2 or more.
RUN mode
:
When Mismatch error, it lights.
Maintenance mode
:
It lights by distance/speed level 1 or more.
RUN mode
:
When Tag communication error, it lights.
Name
Color
Meaning
Green
Yellow
Green
Red
Yellow
Yellow
Yellow
Yellow
Yellow
Yellow
RUN
COMM
NORM
ERR
LV6/7D
LV5/7A
LV4/76
LV3/72
LV2/71
LV1/70
Operation Indicator
Antenna connection port
Conntoroller connection connector
Connect theAntenna connection port to aV680-seriesAntenna.
It is connected with a V680-series Controller.
Connector
Precautions for Correct Use
Safety Precautions
Definition of Precautionary Information
Indicates a potentially hazardous
situation which, if not avoided, could
result in death or serious injury.
Additionally, there may be severe
property damage.
WARNING
Warning
WARNING
This product is not designed for use in directly or
indirectly detecting human bodies in safety-related
applications. Do not use the product as a sensing
device for human protection.
Precautions for Safe Use
Observe the following precautions to ensure safe usage of the product.
1. Do not use the product in environments subject to inflammable,
explosive, or corrosive gases.
2. Do not disassemble, repair, or modify the product in any way.
3. Always lock the lock mechanisms on any devices provided with
them, such as cable connector lock screws.
4. Do not allow water to enter or insert wire in the gaps of the case.
Fire or electric shock may result.
5. Always turn OFF the power supply to the ID Controller before
attaching or removing the Amplifier section.
6.If you suspect that anything is wrong with the product at any
time, stop using it immediately, turn OFF the power supply, and
consult with your OMRON representative.
7. When disposing of the product, dispose of it as industrial waste.
8. Be sure to follow any other warnings, cautions, and notices
given in this manual.
IEC60529 IP67/IP65
(When V680-HS63-W or V680-HS52-W
is connected)
Cable length
Standard length 5m, 10m
100m/s maximun acceleration
2
INSTRUCTION SHEET
TRACEABILITY INFORMATION:
Importer in EU:
Omron Europe B.V.
Wegalaan 67-69
2132 JD Hoofddorp,
The Netherlands
Manufacturer:
Omron Corporation,
Shiokoji Horikawa,
Shimogyo-ku, Kyoto 600-8530 JAPAN
© OMRON Corporation
2006
All Rights Reserved.
Radiated magnetic
field strength
maximum 20 dBμA/m at 10 meters
Suitability for Use
s
Omron Companies shall not be responsible for conformity with any standards,
codes or regulations which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s request, Omron will
provide applicable third party certification documents identifying ratings and
limitations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in
combination with the end product, machine, system, or other application or
use. Buyer shall be solely responsible for determining appropriateness of the
particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
Oct, 2014
D
OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Tokyo, JAPAN
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
Regional Headquarters
Note 1. Consider the height of the DIN Track.
2. Provide a space of at least 10 mm (i.e., at least
two spacers) and attach them securely.