background image

ID System  ID Controller

Safety Precautions

Indicates a potentially hazardous situation which,
if not avoided, could result in death or serious 
injury. Additionally, there may be severe property 
damage.

WARNING

WARNING

This product is not designed for use in directly or indirectly 
detecting human bodies in safety-related applications. Do not 
use the product as a sensing device for human protection.

2.Installation

The product uses the 13.56MHz frequency band to communicate with Tags. Some 
devices, such as some motors, inverters, and switch mode power supplies, 
generate electromagnetic waves (i.e., noise) that can affect communications with 
the Tags. If any of these devices are nearby, communications with Tags may be 
affected or Data Carriers may be destroyed. If the product is to be used near such 
devices, check the effects on communications before using the product.

To minimize the general influence of noise, follow the following precautions:

(1)  Ground the earth terminal of this product and any metallic material located 

around the product to 100

ȍ

 or less.

(2)  Keep product wiring away from high voltage or heavy current.

The product does not provide a water-proof structure. Do not use it where mists 
are present. 

Do not use chemicals that will affect product materials. 

Tighten screws to 1.2 N·m when mounting the product.

Communications performance may be reduced due to mutual interference if more 
than one Read/Write Antenna is installed in the same vicinity. Refer to the 
Read/Write Antenna and Tag Operation Manual (Cat. No. Z248-E1) and confirm 
that there is no mutual interference between Read/Write Antennas. 

3.Storage

Do not store the product in the following locations. 

Locations subject to corrosive gases, dust, dirt, metal powder, or salt

Locations where the specified ambient storage temperature range is exceeded

Locations subject to extreme temperature changes that may result in condensation

Locations where the specified ambient storage humidity range is exceeded

Locations where the product would be directly subjected to vibration or shock 

exceeding specifications

Locations subject to contact with water, oil, or chemical

4.Cleaning

Do not use thinners for cleaning. Resin materials and the case coating will be 

dissolved by thinners,benzenes,acetones and kerosenes.

Precautions for Safe Use

Observe the following precautions to ensure safe usage of the product. 
1. Do not use the product in environments subject to inflammable, explosive, or 

corrosive gases.

2. Do not disassemble, repair, or modify the product in any way. 
3. Tighten the base mounting screws and terminal block screws securely. 
4. Use the specified sizes of crimp terminals for wiring.
5. Always lock the lock mechanisms on any devices provided with them, such as 

cable connector lock screws. 

6. Confirm that the DC power supply is within the rated power supply voltage (24 

VDC +10%/-15%) before using it. 

7. Do not reverse polarity when connecting the power supply. 
8. Do not allow water to enter or insert wire in the gaps of the case. Fire or electric 

shock may result.

9.  Always turn OFF the power supply to the ID Controller before attaching or 

removing the Antenna and Amplifier section. 

10.If you suspect that anything is wrong with the product at any time, stop using it 

immediately, turn OFF the power supply, and consult with your OMRON 
representative.

11. When disposing of the product, dispose of it as industrial waste. 

Model

V680-CA5D01-V2

Definition of Precautionary Information

Warning

Precautions for Correct Use

1. Installation Location

Do not install the product in the following locations:

Locations subject to corrosive gases, dust, dirt, metal powder, or salt

Locations where the specified ambient operating temperature range is exceeded

Locations subject to extreme temperature changes that may result in condensation

Locations where the specified ambient operating humidity range is exceeded

Locations where the product would be directly subjected to vibration or shock 

exceeding specifications

Locations subject to contact with water, oil, or chemicals

General Specifications

Item

Specification

Power supply

 

voltage

(power consumption,
current consumption) 

24 VDC (-15% to +10%) (15 W max.,0.8 A max.)

Ambient operating
temperature

-10 to +55 °C (with no icing) 

Between power supply terminals and GR/Case
Between GR and terminals 

Insulation
resistance

Ambient operating
humidity

25% to 85% (with no condensation)

Dielectric strength

Vibration resistance

Shock resistance

Dimensions

105 x 90 x 65 mm (excluding protrusions) 

Degree of protection

In-panel (equivalent to IP20)

Materials

PC + ABS

Weight

Approx. 300 g

Installation method

DIN Rail or M4 screws

Antenna Connections

V680-CA5D01-V2:1channel, V680-CA5D02-V2:2 channels

Ambient storage 
temperature

-25 to +65 °C (with no icing)

Ambient storage 
humidity

25% to 85% (with no condensation)

10 to 150 Hz with 0.2mm double amplitude and 15m/s

2

maximum acceleration, 10 sweeps of 8 minutes each in three 
directions

150 m/s

2

20 M
(at 500 VDC mega) 

Two, 4.5-dia. mounting holes

65

0

8

18

.

7

15

80

5

90

95

105

5

7.5

Dimensions

External I/O Specifications

Input Specifications 

   (RST, TRG1, and TRG2)

Input impedance
Input current
ON voltage

2.2 k

ȍ

10 mA typical (24 VDC)
19 V min.

Input voltage

24 VDC +10% 
(including ripple) /-15% 
(PNP or NPN)

OFF voltage
I/O response time

5 V max.
70 ms max. 

Output Specifications

(RUN, BUSY/OUT3, ERROR/OUT4, 

OUT1 and OUT2)

Leakage current
Residual voltage

ȝ

A max.

2.0 V max.

Maximum
switching
capacity

24 VDC +10% (including ripple)

              -15%

The CPU will stop operation and the RST indicator 
will light when the RST input is turned ON. The 
ERROR output will be reset at that time.

100mA photo MOS outputs (PNP or NPN)

Note 1:

The transistor may be damaged if an output is shorted 
with no load connected. 

2:

95±0.2

2.

0

±

0

8

Two, M4

Mounting Hole Dimensions

A

B

When mounting the ID
Controller to DIN Rail, hook 
the ID Controller at point A 
and then press in direction B.

To remove the ID Controller 
from the DIN Rail, pull out 
the mounting hook. 

Recommended DIN Rail: PFP-100N2
(rail length: 1 m) 
(manufactured by OMRON)

When mounting directly to a control panel, always use flat washers and M4 screws.
Tightening torque: 1.2 N·m

Installation Methods

Mounted on a Panel

●Mounting to DIN Rail

(1)

(2)

I/O Device Wiring Example

Ɣ3/&2XWSXW8QLW

Ɣ131

 Transistor 

   Open-collector 
   Output 

(e.g., from a 3-wire 
 Sensor)

Ɣ&RQWDFW2XWSXW

(e.g., Pushbutton 
 Switch)

(e.g., C200H-OD21 
 or C500-OD412)

24-VDC

power

supply

+V

OUT

0 V(COM)

+V

0 V

Output

RST

TRG1

TRG2

ID Controller Input Section

COM_I

2.2 kW

2.2 kW

2.2 kW

la

nr

et

nI

sti

uc

ri

Ɣ3/&,QSXW8QLW

Ɣ5HOD\

(e.g. C200H-ID212 
 or C500-ID218)

COM

IN

IN

RUN

BUSY/OUT3

ERROR/

OUT4

OUT1

OUT2

COM_O

Inputs

Outputs

la

nr

et

nI

sti

uc

ri

la

nr

et

nI

sti

uc

ri

la

nr

et

nI

sti

uc

ri

r

os

ne

S

la

nr

et

ni

sti

uc

ri

c

+

la

nr

et

nI

sti

uc

ri

la

nr

et

nI

sti

uc

ri

ID Controller Input Section

la

nr

et

nI

sti

uc

ri

la

nr

et

nI

sti

uc

ri

la

nr

et

nI

sti

uc

ri

la

nr

et

nI

sti

uc

ri

la

nr

et

nI

sti

uc

ri

24-VDC

power

supply

+

Between power supply terminals and GR/Case
Between GR and terminals 

1,000VAC
50/60Hz for 1 minute.

V680-CA5D02-V2

Applicable Standards

1.

UL Standards

UL (Underwriters Laboratories Inc.) conditions have been met.
UL508

Use the product connected to one of the following two circuits. 
(1) Limited Voltage/Current Circuit (Approved in UL508)

A circuit that uses as its power supply the secondary coil of an insulated 
transformer that satisfies the following conditions:

Maximum voltage (with no-load): 30 Vrms (42.4 V peak) OR

Maximum current: (1) 8 A (including when shorted) OR

(2) A current restricted by a circuit protective device 

(e.g., fuse) with the following ratings

No-load voltage (V peak)

0 to 20

Maximum current rating (A)

5.0

Over 20 to 30

100

Peak voltage

(2)A circuit with a maximum voltage of 30 Vrms (42.4 V peak) that uses as its 

power supply a Class 2 power supply defined in UL1310 or a Class 2 
transformer defined in UL1585.

2.

EMC Standards

The repuirements of the EC Directive have been satisfied.
EMC Directives::EN 61000-6-2.EN 61000-6-4

Manufacturer:
  Omron Corporation,
  Shiokoji Horikawa, Shimogyo-ku,
  Kyoto, 600-8530 JAPAN

TRACEABILITY INFORMATION:
Importer  in EU :
  Omron Europe B.V.
  Wegalaan 67-69
  2132 JD Hoofddorp,
  The Netherlands

Notice:
This is a class A product. In residential areas it may cause radio 
interference, in which case the user may be required to take adequate 
measures to reduce interference.

© OMRON Corporation  

2007

  All Rights Reserved.

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet pri-
marily describes precautions required in installing and
operating the product.
Before operating the product, read the sheet thoroughly to
acquire sufficient knowledge of the product. For your con-
venience, keep the sheet at your disposal.

Notice for Korea Radio Law

A급 기기(업무용 방송통신기자재)
이 기기는 업무용(A급) 전자파적합기기로서 판매자
또는 사용자는 이 점을 주의하시기 바라며,가정외의
지역에서 사용하는 것을 목적으로 합니다.

Suitability for Use

s

Omron Companies shall not be responsible for conformity with any standards, 
codes or regulations which apply to the combination of the Product in the 
Buyer’s application or use of the Product. At Buyer’s request, Omron will 
provide applicable third party certification documents identifying ratings and 
limitations of use which apply to the Product. This information by itself is not 
sufficient for a complete determination of the suitability of the Product in 
combination with the end product, machine, system, or other application or 
use. Buyer shall be solely responsible for determining appropriateness of the 
particular Product with respect to Buyer’s application, product or system. 
Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

O c t ,   2 0 1 4

D

OMRON Corporation

      Industrial Automation Company

 Contact:  www.ia.omron.com

Tokyo, JAPAN

OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 
Alexandra Technopark, 
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 
200 Yin Cheng Zhong Road, 
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON EUROPE B.V.
Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

Regional Headquarters

Reviews: