42
Types of Commands and Responses
Section 4-4
Response Format
1-to-n Procedure
Command Format
Response Format
4-4-12 Write Processing Repeat Command (RP)
Executes the processing the write command previously executed.
Command Format
Response Format
M D 7 5 CR
∗
End code
75: The number of overwriting operations has not exceeded the allowable number.
76: The number of overwriting operations has exceeded the allowable number.
Header
@ Unit no M D S/L 1 X X X X X X FCS
∗
Header
00 to 07
Read/Write head word (fixed to 1)
First address specification
Specifies a hexadecimal value (00
H
, 01
H
, 02
H
,...,
FF
H
) for the number of overwriting operations to be
added.
Mode specification
S: Subtraction method used. The allowable number of
overwriting operations is specified by the user
(16,700,000 max.) Note that the specification for the
allowable number of overwriting operations for an
EEPROM-type Data Carrier is 300,000 at
temperatures of less than 40
°
C.
L: Addition method used. When using this command,
the allowable number of overwriting operations is
100,000.
@ Unit no M D 7 5 FCS
∗
End code
75: The number of overwriting operations has not exceeded the allowable number.
76: The number of overwriting operations has exceeded the allowable number.
Header
00 to 07
R P CR
Header
∗
Terminator
X X 0 0 CR
∗
ASCII/HEX code specification
A: ASCII code, JIS 8 code
H: HEX code
R/W Head No. specification
(fixed to 1)
Summary of Contents for V600 RFID System
Page 1: ...OPERATION MANUAL Cat No Z193 E1 01 Board Type ID Controller V600 RFID System V600 CM1D...
Page 2: ...V600 RFID System V600 CM1D Board Type ID Controller Operation Manual Produced December 2003...
Page 3: ...iv...
Page 7: ...viii...
Page 10: ...xii...
Page 16: ...6 User I O Section 1 4...
Page 24: ...14 Outline Size Section 2 5...
Page 60: ...50 Communication Time Section 4 6...
Page 82: ...72 Index...
Page 84: ...74 Revision History...
Page 87: ...V6001 RFID System V600 CM1D Board Type ID Controller Cat No Z193 E1 01 OPERATION MANUAL...