5
User I/O
Section 1-4
1-4
User I/O
The ID Controller is equipped with two user outputs that can be turned ON/
OFF by a command from the host controller, and also two user inputs whose
ON/OFF status can be read. These I/Os can be manipulated independently of
each other, so that ON/OFF signals can be processed easily and at low cost
by a host computer. The following figure shows an example in which the ID
Controller is used for batch reading of test data.
Outline of Operation
1,2,3...
1.
When there is a workpiece to be tested, the PC controlling the line instructs
the conveyor to stop the workpiece at a predetermined place.
2.
When the workpiece has been stopped, the PC issues a signal indicating
that the line control action has been completed.
3.
A host computer reads the signal to the ID Controller through a user input,
and reads the test data.
4.
When the test data has been read, the host computer issues a data collec-
tion completion signal through the user output of the ID Controller.
5.
In response to the data collection completion signal, the PC sends the
workpiece to the next process.
Line control end input
Data collection end output
Inspection processing
Pallet
To next processing
Conveyor
Workpiece to
be inspected
Line control PC
ID Controller
Host computer for
collecting inspection data
Summary of Contents for V600 RFID System
Page 1: ...OPERATION MANUAL Cat No Z193 E1 01 Board Type ID Controller V600 RFID System V600 CM1D...
Page 2: ...V600 RFID System V600 CM1D Board Type ID Controller Operation Manual Produced December 2003...
Page 3: ...iv...
Page 7: ...viii...
Page 10: ...xii...
Page 16: ...6 User I O Section 1 4...
Page 24: ...14 Outline Size Section 2 5...
Page 60: ...50 Communication Time Section 4 6...
Page 82: ...72 Index...
Page 84: ...74 Revision History...
Page 87: ...V6001 RFID System V600 CM1D Board Type ID Controller Cat No Z193 E1 01 OPERATION MANUAL...