SECTION 7
Host Communications
Normal Communications
While the
Read
Screen is displayed, communications will be performed through the
serial interface with a computer or PLC using the normal communications format.
Set the
System Set./Com Mode
to
Normal
.
n
Command List
§
Designating Controller Operation
The following commands designate Controller operation, such as executing reading
and switching read conditions.
§
Backing Up and Uploading Data
The following commands back up or upload settings to/from a Memory Card or the
host.
Command
Function
Page
@GL
Performs one reading.
@SC
Stops continuous reading.
@RD
Outputs read data to the serial interface (polling).
@GT
Executes teaching.
@GM
Switches the trigger mode.
@GR
Switches the read mode.
@SN
Gets or switches read conditions.
@PC
Switches the Camera.
@DC
Switches the screen display status between a still image and a live
image.
@WF
Starts/stops the Watcher function.
@WD
Switches the display on the Watcher Screen between the 2D Code
Checker and the Condition Watcher.
@WR
Clears Watcher data.
@TS
Sets the date and time.
Command
Function
Page
@MB
Backs up settings in Memory Cards.
@MU
Uploads settings from Memory Cards.
@CB
Backs up settings in the host.
@CU
Uploads settings from the host.
@SV
Saves settings to flash memory.