Regular Inspections
To maintain the V530-R160 in the best condition, perform the following regularly.
Clean the Lens and LED indicators with a lens-cleaning wipe or blow off dust with an aerosol air
sprayer.
Lightly wipe off dirt with a soft cloth.
• Turn OFF the power and take safety precautions before conducting inspections.
• Do not use thinners or benzene.
Inspection point
Details
Tools required
Power supply
The voltage measured at the power supply terminals on
the terminal block must be 20.4 VDC to 26.4 VDC.
Circuit tester
Ambient temperature
The operating ambient temperature inside the cabinet
must be between 0 to 50
°
C.
Thermometer
Ambient humidity
The operating ambient humidity inside the cabinet must be
between 35 and 85%.
Hygrometer
Installation
Each cable connector must be correctly inserted and
locked.
The cameras must be firmly secured.
The camera lens mounts must be firmly secured.
Screwdriver
LED lights
All indicators must light when the power is turned ON.
• Verify that a through-image is displayed.
• When using an Intelligent Lighting, verify that the light