229
V530-R160
Operation Manual
SE
C
T
IO
N
8
Serial Interf
ac
e (Norma
l)
SECTION 8
Communication with the Host
Connection Examples for Programmable Controller (Normal)
This is a connection example using the CQM1H programmable controller made by OMRON.
The flow is such that a read command [@GL] is input from the programmable controller to the
controller, then the controller outputs the judgement result to the programmable controller.
System Configuration
RS-232C Cable Wiring (XW2Z-200T/XW2Z-500T)
The maximum cable length is 15 m.
VISION MATE
CONTROLLER
V530-R160
Power supply
POWER
SYNC
Camera
Synchronous sensor
Monitor
Programmable Controller
Controller
RS-232C cable
XW2Z-200T (2 m)
XW2Z-500T (5 m)
CPU unit: CQM1H-CPU*
Power supply: CQM1-PA**
Pin
Controller
Signal
SD
RD
NC
RDB(RD+)
GND
Hood
2
3
4
5
9
Pin
Programmable Controller
Signal
SD
RD
RS
CS
GND
2
3
4
5
9
Hood
Only use a shielded cable.