xiv
Installation Precautions
3
Scanner
• We recommend holding the Scanner as shown below.
• Do not apply excessive force to the Scanner.
• Do not pull on the cable.
V530-H303 Scanner
• The thickness of glass being read must be 1 mm or less.
• The distance of the center of the code from the edge of the glass
is 7 mm, 10 mm, or 13mm.
• To change the distance, loosen the two screws on the reading
section, adjust the stopped to the desired position, and then
retighten the screws. The screws are M2 x 4 pan-head tapping
screws.
• The field of vision is 6 mm. Adjust the above stopped according
to the size and position of the code.
7mm
10mm
13mm
T1 mm
Screws: Pan-head tapping
screws, M2 x 4