![Omron V520-LHA7127 User Manual Download Page 24](http://html1.mh-extra.com/html/omron/v520-lha7127/v520-lha7127_user-manual_744094024.webp)
15
Section 4 - Configuring the Scanner
V520-LHA7127
Section 4
Configuring the Scanner
Since the operation of the V520-LHA7127 scanners are microprocessor controlled, it is possible to modify or
program its operation to match your specific application. Changes in parameter settings can be changed or
programmed in two ways.
1.
The first method employs specially designed programming bar codes which instruct the scanner to modify
specific parameters.
2.
The scanner can also be programmed by sending software instructions from the host PC to the scanner via
the RS-232C connection.
Programming Menus & Commands
Appendix A contains full instructions on how to configure the scanner as well as a complete listing of the
computer commands and programming bar codes that are available to customize the scanner for your
application.
Default Settings
When you modify or change any parameters, the scanner can be programmed to retain the new parameter in
memory, even if power is interrupted or terminated. If for any reason the scanner is instructed to “return all
parameters to default settings,” it will return to the U1 default settings.
Default settings are indicated by a pointing hand symbol (
%
) throughout the menus to follow
To restore the “out of box” factory settings shown in the following table, use the settings U1, P0, B5, B6 and S7
settings in combination. See page 23 for instructions under “Preprogrammed Unit.”
Parameter
Factory Default Setting
RS-232C Communications
9600 baud (U1)
8 data bits (U1)
1 stop bit (U1)
No parity (U1)
No handshaking (P0)
Scan Rate
700 Scans/Second (U1)
Trigger Function
Disabled (S7)
Read Mode
Multiple read mode (U1)
Redundant Decodes
None (Read Once) (U1)
Bar Code
Symbologies
WPC (U1), 2 of 5 (U1), NW-7 (U1), Code 39 (U1)
Code 93 (B5), Code 128 (B6)
IATA, MSI
Disabled (U1)
Buzzer
Maximum volume (U1)
After decode 3kHz, 2kHz (U1)
After decode duration 200 ms (U1)
Error Indications
No bad read (U1)
Good Read LED
After decode 200 ms (U1)
Filter
Output from low and High Gain (U1)
Summary of Contents for V520-LHA7127
Page 1: ...MANUAL USER Cat No Q07BAZ1 V520 LHA7127 Miniature High Speed CCD Fixed Position Scanner...
Page 2: ...V520 LHA7127 Miniature High Speed CCD Fixed Position Scanner User Manual...
Page 3: ...iv...
Page 9: ...x Application Precautions 3...
Page 25: ...16 Section 4 Configuring the Scanner V520 LHA7127...
Page 27: ...18 Section 5 Application Engineering Support V500 LPN5627 V500 LPR5627...
Page 29: ...20 Section 6 Scanner Servicing and Maintenance V520 LHA7127...
Page 69: ...60 Appendix B Dimensional Drawings V520 LHA7127...
Page 71: ...62 Appendix C Optical Performance Charts V520 LHA7127...
Page 75: ...66 Appendix D PLC Touchscreen Connection Examples V520 LHA7127...