PRECAUTION ON SAFETY

Meanings of Signal Words

Indicates  a  potentially  hazardous  situation 

which, if not avoided, will result in minor or 

moderate  injury,  or  may  result  in  serious 

injury  or  death.  Additionally  there  may  be 

significant property damage.

WARNING

Meanings of Alert Symbols

A lithium battery is built into the 2D Code reader and 

may occasionally combust,explode, or burn if not 

treated properly.

Dispose of the Controller as industrial waste, and 

never disassemble, apply pressure that would deform, 

heat to 100  or higher, or incinerate the 2D Code 

reader.

WARNING

This product is not designed or rated for ensring safty 

of persons.

Do not use it for such purposes.

Observe the following precautions to ensure safe use of the product.

1.Installation Environment Precautions

(1)Do not use the 2D code reader in environments with flammable 

or explosive gases.

(2)Please avoid setting up in outdoor and using it.

2.Power Supply and Wiring Precautions

(1)Use the 2D code reader with the power supply voltages specified 

in this manual.

(2)Use the cables specified in this manual.

(3)Keep the power supply cable as short as possible (10 m maximum).

(4)Use a DC power supply with countermeasures against high-voltage 

spikes (safe extra low-voltage circuits on the secondary side).

3.Other Precautions

(1)Do not attempt to disassemble, repair, or modify the 2D code 

reader. Doing so may cause product failure or a fire.

(2)If abnormal odors, heating, or smoke occurs, stop using the 2D 

code reader immediately,turn OFF the power, and consult with 

your OMRON representative.

(3)When disposing of the 2D code reader, treat it as industrial waste.

(4)When disposing of the 2D code reader, do not apply pressure that 

would deform.

Precaution for Safe Use

1.Environment

Do not install the product in the following locations:

(1)Locations where the ambient temperature exceeds the rated 

temperature range. 

(2)Locations subject to rapid changes in temperature (causing 

condensation).

(3)Locations where the relative humidity exceeds the rated 

humidity range.

(4)Locations subject to corrosive or flammable gases.

(5)Locations where dust, salt, or metallic powder accumulate on 

the 2D code reader.

(6) Locations subject to direct vibration or impact outside the 

specified ranges.

(7)Locations subject to direct sunlight.

(8)Locations subject to exposure to oil, chemicals, etc.

2.Installation and Handling of Components

(1) Use the cables and the power supply specified in this manual.

3.Attaching and Removing Cables

(1)Do not connect a cable to the 2D Code Reader if the other end of 

the cable is connected to a personal computer or a Programmable 

Controller.

(2)To prevent damage from static electricity, use a wrist strap or 

another device for preventing electrostatic charges when touching 

terminals or signal lines.

4.Memory Cards

(1)Do not remove the Memory Card when the Memory Card indicator is lit.

The Memory Card or the Code Reader may be damaged.

5.Turning OFF the Power Supply

(1)Do not turn OFF the power supply while a message is being displayed 

indicating that processing is being performed. Data in memory will be 

destroyed, and the 2D code reader may not operate correctly the next 

time it is started.

Precaution for Correct Use

V400-AC2

Materials

PC  Contact part:

Silicone Gum

(antistatic grade)

Approx.20g

Operating method

V400-AC2/AC3(CONTACTOR;OPTION)

V400-H111/211/111-1(MAIN UNIT)

Dimensions

V400-H111/211/111-1

V400-AC3

V400-H211

40 mm (Contact with the Contactor)

5VDC 10%

V400-H111

5 to 10 mm

15 to 30 mm

1A  max.

RS-232C

DataMatrix ECC2000 10 10 to 64 64,

8 18 to 16 48

QR Code    Model 1or 2  21 21 to 57 57

(Version 1 to Version 10)

Pushbutton control using the TRIGGER Button

Uploading settings by communications 

command or from Memory Card.
SD Card

1.8-inch TFT liquid crystal image and read 

data display.
POWER indicator

Operating: 0 to 40 ; Storage: -25 to 60

35% to 85% (with no condensation)

No corrosive gases

10 to 150 Hz; half-amplitude: 0.35 mm 

(max. acceleration: 50 m

2

/s)

150 m

2

/s 3 times in 6 directions

Approx.230g

IEC60529 IP64

Case: ABS; optical surface: PC; surfaces: PMMA

Fleld of vision

Working distance

Power supply voltage

Current consumption

Serial interface

Applicable code

Operating method
Settings
Memory Card
Monitor
Indicators

Ambient temperature

Ambient humidity

Ambient environment
Vibration resistance
Shock resostance

Weight

Degree of protection

Materials

3 mm

V400-H111-1

This product is compliant with the standards below:

   EN Standards(European Standards), EN61326-1

   Electromagnetic environment : Industrial electromagnetic environment

   (EN/IEC 61326-1 Table 2)

Also, the following condition is applied to the immunity test of this product.

  : If the level of disturbance of the video is that with

    characters on the monitor are readable, the test is pass.

Regulations and Standards

V400-W20-2M/W21-2M/W22-2M(CABLES;OPTION)

Operating: 0 to 40 ; Storage: -25 to 60

35% to 85% (with no condensation)

No corrosive gases

Ambient temperature

Ambient humidity

Ambient environment

Cable sheathing: Heat-resistant vinyl chloride

Special connector: PPS, PBT, POM

D-sub connector: ABS

Approx.100g

Materials

Operating method

30 mm

Minimum

bending radius

V400-W21-2M

V400-W20-2M

Male,9-pin D-sub

Interface connector

Brown:+5V  Blue:GND

Power Supply

Female,9-pin D-sub

V400-W22-2M

V600-A22,

(OPTION)

Approx.110g

2 Ferrite core

Accessory

Specifications

V400-AC3

PC  Contact part:

POM

(White)

V400-W22-2M

V400-AC2

(Unit:mm)

64

45

55

34

225

100

MEMORYCARD

INSERT HOLE

ZOOM LEVER

LCD MONITOR

OPERATING INDICATOR(GREEN)

TRIGGER SWITCH

BUZZER

LIGHTING

READING POINT

LIGHTING

4-M2 CONTACTOR

MOUNTING HOLES

V400-W20-2M/V400-W21-2M

(Unit:mm)

29.8

75

2000

20

200

30

12.6Dia.

CONNECTOR

BAND,BINDING

BUSH,CORD

VINYL INSULATED ROUND

CORD 5Dia.4CORES

NAME PLATE

D-SUB 9PINS

CONNECTOR

(Unit:mm)

29.8

75

2000

200

30

12.6Dia.

CONNECTOR

BAND,BINDING

BUSH,CORD

VINYL INSULATED ROUND

CORD 5Dia.4CORES

NAME PLATE

VINYL INSULATED FRAT

CORD 2DiaX2 2CORES

CONNECTOR

D-SUB 9PINS

CONNECTOR

(Unit:mm)

4-M2 MOUNTING SCREWS

109

43.5

100

34

40

57

(Unit:mm)

109

43.5

100

34

4-M2 MOUNTING SCREWS

57

40

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 

measures to reduce interference.

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

TRACEABILITY INFORMATION:

Importer  in EU :

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

© OMRON Corporation  

2005

  All Rights Reserved.

                                                               

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet 

primarily describes precautions required in installing and 

operating the product.

Before operating the product, read the sheet thoroughly to 

acquire sufficient knowledge of the product. For your 

convenience, keep the sheet at your disposal.

• Notice for Korea Radio Law

A급 기기(업무용 방송통신기자재)
이 기기는 업무용(A급) 전자파적합기기로서 판매자
또는 사용자는 이 점을 주의하시기 바라며,가정외의
지역에서 사용하는 것을 목적으로 합니다.

Suitability for Use

s

Omron Companies shall not be responsible for conformity with any standards, 

codes or regulations which apply to the combination of the Product in the 

Buyer’s application or use of the Product. At Buyer’s request, Omron will 

provide applicable third party certification documents identifying ratings and 

limitations of use which apply to the Product. This information by itself is not 

sufficient for a complete determination of the suitability of the Product in 

combination with the end product, machine, system, or other application or 

use. Buyer shall be solely responsible for determining appropriateness of the 

particular Product with respect to Buyer’s application, product or system. 

Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 

SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND 

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 

EQUIPMENT OR SYSTEM.

See also Product catalog for Warranty and Limitation of Liability.

Oct, 2014

D

OMRON Corporation

      Industrial Automation Company

 Contact:  www.ia.omron.com

Tokyo, JAPAN

OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A.

Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 

Alexandra Technopark, 

Singapore 119967

Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON EUROPE B.V.

Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen, Germany

Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

Regional Headquarters

Reviews: