![background image](http://html1.mh-extra.com/html/omron/v400-h/v400-h_datasheet_741428003.webp)
A-3
C400
C400
Rating and Specifications
Item
V400-H111
V400-H211
Field of vision
5 × 5 to 10 × 10 mm
15 × 15 to 30 × 30 mm
Working distance
40 mm (flush when Contactor is mounted)
Power supply
5 VDC ±10%
Current consumption
1.0 A max.
Serial interface
RS-232C
Applicable codes
Data Matrix, ECC200, 10 × 10 to 64 × 64, 8 × 18 to 16 × 48, QR Code (Models 1, 2),
21 × 21 to 57 × 57 (Versions 1 to 10)
Operation method
Pressing the trigger button
Settings
Make settings by using the manual setting window, uploading from an SD Memory Card,
or by using Support Software.
Memory card
SD Memory Card
Monitor
1.8 inch TFT LCD, displaying images and read data
Display illumination
Operation display, memory card access
Ambient temperature
Operation: 0 to 40 °C; storage: -25 to 60 °C
Ambient humidity
35 to 85% (with no condensation)
Ambient conditions
No corrosive gases
Vibration resistance
10 to 150 Hz, single amplitude 0.35 mm (50 m
2
/s max. acceleration)
Shock resistance
150 m
2
/s in ±X, Y, and Z directions, 3 times
Weight
Approx. 230 g
Degree of protection
IEC 60529 IP64
Materials
Case: ABS; optical surface: PC; display surface: PMMA