background image

A-3

C400

C400

Rating and Specifications

Item

V400-H111

V400-H211

Field of vision

5 × 5 to 10 × 10 mm

15 × 15 to 30 × 30 mm

Working distance

40 mm (flush when Contactor is mounted)

Power supply

5 VDC ±10%

Current consumption

1.0 A max.

Serial interface

RS-232C

Applicable codes

Data Matrix, ECC200, 10 × 10 to 64 × 64, 8 × 18 to 16 × 48, QR Code (Models 1, 2), 

21 × 21 to 57 × 57 (Versions 1 to 10)

Operation method

Pressing the trigger button

Settings

Make settings by using the manual setting window, uploading from an SD Memory Card, 

or by using Support Software.

Memory card

SD Memory Card

Monitor

1.8 inch TFT LCD, displaying images and read data

Display illumination

Operation display, memory card access

Ambient temperature

Operation: 0 to 40 °C; storage: -25 to 60 °C

Ambient humidity

35 to 85% (with no condensation)

Ambient conditions

No corrosive gases

Vibration resistance

10 to 150 Hz, single amplitude 0.35 mm (50 m

2

/s max. acceleration)

Shock resistance

150 m

2

/s in ±X, Y, and Z directions, 3 times

Weight

Approx. 230 g

Degree of protection

IEC 60529 IP64

Materials

Case: ABS; optical surface: PC; display surface: PMMA