Appendices
A-4
NY-series Industrial Panel PC / Industrial Box PC Built-in EtherNet/IP Port User’s Manual (W563)
Use the Network Configurator if a CS-/CJ-series PLC operates as the originator device.
*1 Variables with its Network Publish attribute set to
Output
or
Input
in the Global Variable Table are called net-
work variables.
A-2-2
Procedure to Make the EtherNet/IP Connection Settings with the
Sysmac Studio
1
Registering devices
•
Main Window
Register devices with which the EtherNet/IP connec-
tions are established to the project.
Setup Window
2
Creating network variables(*1)
...
work Variable for the Origi-
nator Device
Global Variable Table on the
Sysmac Studio
3
Registering tags and tag sets
...
Refer to
on page A-13.
EtherNet/IP Connection Set-
tings (Tag Set Display)
Register the network variables that are set in step 2 as
tags and tag sets.
4
Setting Connections
...
on
EtherNet/IP Connection Set-
tings (Connections Display)
Specify devices (i.e., target devices and originator
devices) and tag sets to communicate with using the
EtherNet/IP connections.
5
Going online from the Sysmac
Studio
...
on
•
Main Window
6
Downloading EtherNet/IP con-
nection settings
Note
Connections automatically
start after the download.
...
on
•
Synchronization Window /
Transfer to Controller Dia-
log Box
•
EtherNet/IP Connection
Settings
7
Checking operation
Stopping and starting connections
...
Refer to
Communications Status with
the Sysmac Studio and Trou-
bleshooting
on page A-33.
EtherNet/IP Connection
Monitor Tab Page
NY-series Controller
CS-/CJ-series PLC
Settings for the target device
Settings for the originator device
Setting only with
the Network Configurator is possible.