Efficient and effective
The machine controller for Lean automation solutions
The CP1E N-type CPU units are equipped with high-speed counters, pulse outputs, and a built-
in serial port. These features enable control of a wide range of devices.
optional units for more flexibility
Three expansion units are available. An option board for an additional serial communication port can be added to N-type CPU unit.
Pulse outputs
Two 100kHz pulse outputs for high-precision position
control.
Note : models with transistor outputs.
High-speed counters
Control multiple axes with one PLC using the two 100kHz
and four 10kHz, single-phase high-speed counters.
modbus-RTU easy master
Fast inverter control via RS-485.
Serial PLC links
Link data with up to 10 words between up to nine CP1E-N CPU
units.
Hmi
connection
High-speed
counters
Pulse outputs
modbus-RTU
master
Built-in RS-232C
Built-in USB
Serial option port
RS-485
Pulse
outputs
HMI
HMI
Inverter
RS-485
RS-232C
RS-232C
Inverter
Rotary
encoder
Polling unit
Polling Unit
Polled Node No. 0
Polled Node No. 7
Polling Unit
Polled Node No. 0
Polled Node No. 7
Polling Unit
Polled Node No. 0
Polled Node No. 7
Polled node
No. 0
Polled node
No. 7
CJ1M CPU units
can also be
connected.
High-speed counter
Servomotor / driver
Rotary encoder
General-purpose motor
High-speed
counter
Option units
Expansion units and expansion I/O units
N-type CPU Unit with 30 or 40 I/O Points
RS-232C
option Board
CP1W-CIF01
Units with 40 i/o
CP1W-40EDR / CP1W-40EDT /
CP1W-40EDT1
Units with 20 i/o
CP1W-20EDR1 / CP1W-20EDT /
CP1W-20EDT1
Units with 32 outputs
CP1W-32ER / CP1W-32ET /
CP1W-32ET1
analog i/o Unit
CP1W-MAD11
analog input Unit
CP1W-AD041
analog output Unit
CP1W-DA041
CompoBus/S
CP1W-SRT21
Profibus-DP
CPM1A-PRT21
DeviceNet
CPM1A-DRT21
Units with 16 outputs
CP1W-16ER / CP1W-16ET /
CP1W-16ET1
Units with 8 outputs
CP1W-8ER / CP1W-8ET /
CP1W-8ET1
Unit with 8 inputs
CP1W-8ED
Temperature
Sensor Units
(Thermocouples)
CP1W-TS001
CP1W-TS002
Temperature
Sensor Units
(Platinum
Resistance
Thermometers)
CP1W-TS101
CP1W-TS102
RS-422a/485 option Board
CP1W-CIF11
(Maximum transmission
distance: 50m)
RS-422a/485 option Board
(Isolated-type)
CP1W-CIF12
(Maximum transmission
distance: 500m)
Expansion Units and Expansion I/O Units
Expansion I/O Units
Analog I/O Units
Temperature Sensor Units
Fieldbus slaves
CPM1A expansion units can be used under the same conditions as for the CP1W.
E-type CP1E CPU Units (Basic models)
Product Name
Specifications
model
Power supply
inputs
outputs
output type
Program
Capacity
Data memory
capacity
E-type with 20 I/O Points
100 to 240 VAC
12
8
Relay
2K steps
2K words
CP1E-E20DR-A
E-type with 30 I/O Points
18
12
Relay
CP1E-E30DR-A
E-type with 40 I/O Points
24
16
Relay
CP1E-E40DR-A
N-type CP1E CPU Units (application models)
Product Name
Specifications
model
Power supply
inputs
outputs
output type
Program
Capacity
Data memory
capacity
N-type with 20 I/O Points
100 to 240 VAC
12
8
Relay
8K steps
8K words
CP1E-N20DR-A
12 D 2 Analog* 8 D 1 Analog*
CP1E-NA20DR-A*
12
8
Transistor (sinking)
CP1E-N20DT-A
Transistor (sourcing)
CP1E-N20DT1-A
24 VDC
12
12
Relay
CP1E-N20DR-D
Transistor (sinking)
CP1E-N20DT-D
Transistor (sourcing)
CP1E-N20DT1-D
12 D 2 Analog* 8 D 1 Analog*
Transistor (sinking)
CP1E-NA20DT-D*
Transistor (sourcing)
CP1E-NA20DT1-D*
N-type with 30 I/O Points
100 to 240 VAC
18
12
Relay
8K steps
8K words
CP1E-N30DR-A
Transistor (sinking)
CP1E-N30DT-A
Transistor (sourcing)
CP1E-N30DT1-A
24 VDC
Relay
CP1E-N30DR-D
Transistor (sinking)
CP1E-N30DT-D
Transistor (sourcing)
CP1E-N30DT1-D
N-type with 40 I/O Points
100 to 240 VAC
24
16
Relay
8K steps
8K words
CP1E-N40DR-A
Transistor (sinking)
CP1E-N40DT-A
Transistor (sourcing)
CP1E-N40DT1-A
24 VDC
Relay
CP1E-N40DR-D
Transistor (sinking)
CP1E-N40DT-D
Transistor (sourcing)
CP1E-N40DT1-D
Battery Set
For N-type CP1E CPU Units
Note: Mount a Battery to an N-type CP1E CPU Unit if the data in the following areas must be backed up for power interruptions. DM Area (D)
(except backed up words in the DM Area), Holding Area (H), Counter Completion Flags (C), Counter Present Values (C), Auxiliary Area (A), and
Clock Function.(Use batteries within two years of manufacture.)
CP1W-BAT01
Note: There are no accessories included with N-type CP1E CPU units. RS-232C connectors for the built-in RS-232C port and the battery (CP1W-BAT01) are not included.
*Note: CP1E-NA model available early 2010