3-4
General Specifications for 3G3HV Inverters
D
200-V Class
Model
3G3HV-
j
-CE
AB004 AB007 AB015 AB022 AB037
Maximum applica-
ble motor capacity
(kW)
0.4
0.75
1.5
2.2
3.7
Output characteristics
Rated output
capacity (kVA)
1.2
2.3
3.0
4.2
6.7
Rated output
current (A)
3.2
6
8
11
17.5
Maximum out-
put voltage (V)
3-phase, 200 to 230 VAC
(Corresponds to input voltage.)
Maximum out-
put frequency
(Hz)
400 Hz (Set by parameter constant.)
Power supply characteristics
Rated voltage
(V)
Rated frequen-
cy (Hz)
Single-phase, 200 to 230 VAC, 50/60 Hz
Allowable volt-
age fluctuation
–15% to 10%
Allowable fre-
quency fluctua-
tion
±
5%
Heat generated
(kW)
0.07
0.09
0.12
0.14
0.22
Weight (kg)
Approx.
3
Approx.
4.5
Approx.
4.5
Approx.
6
Approx.
6
D
400-V Class
Model
3G3HV-
j
-CE
A4004
A4007
A4015
A4022
A4037
A4055
A4075
A4110
A4150
B4185
B4220
B4300
B4370
B4450
B4550
B4750
B411K B416K
Maximum applica-
ble motor capacity
(kW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
110
160
Output characteristics
Rated output
capacity (kVA)
1.4
2.6
3.7
4.7
6.1
11
14
21
26
31
40
50
61
73
98
130
170
230
Rated output
current (A)
1.8
3.4
4.8
6.2
8
14
18
27
34
41
52
65
80
96
128
165
224
302
Maximum out-
put voltage (V)
3-phase, 380 to 460 VAC (Corresponds to input voltage.)
Maximum out-
put frequency
(Hz)
400 Hz (Set by parameter constant.)
Power supply characteristics
Rated voltage
(V)
Rated frequen-
cy (Hz)
3-phase, 380 to 460 VAC, 50/60 Hz
Allowable volt-
age fluctuation
–15 to 10%
Allowable fre-
quency fluc-
tuation
±
5%
Heat generated
(kW)
0.06
0.09
0.11
0.13
0.15
0.22
0.36
0.46
0.57
0.66
0.88
1.1
1.3
1.4
1.9
2.4
3.1
4.2
Weight (kg)
Approx.
3
Approx.
3
Approx.
4
Approx.
4.5
Approx.
4.5
Approx.
6.0
Approx.
6.0
Approx.
11
Approx.
11
Approx.
29
Approx.
31
Approx.
44
Approx.
44
Approx.
44
Approx.
81
Approx.
82
Approx.
135
Approx.
145
Specifications
Chapter 3
AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]