177
F3SJ-A
User’s Manual
Ch
apt
e
r
5
Wir
ing
Ex
amples
Input/Output Circuit and Applications
E
Connecting to a G9SB-301-D
•Thin (22.5mm thick)
Use G9SB-301-B for 3a+1b contact auto reset type.
Use G9SB-200-D for 2a contact manual reset type, or G9SB-200-B for 2a contact auto reset type. For details, see the
catalogs.
OUT
PLC
KM1
KM2
IN1
IN2
KM3
A1
14
24 34 42
41
33
23
13
T32
T31
T11
A2
G9SB-301-D
KM1
KM2
T12
K1
K1
K2
K1
S2
S1
a K2
Control
Circuit
a
T21
T22
K2
K2
K1
F39-JC A-L
F39-JC A-D
TH
SA
+DC24V
0V
E1
*1
*1
*1
*1
M
*2
12
21
22
S3
KM1
KM2
Emitter
Receiver
Shield
0V (Blue)
Open
Test input (Green)
Reset input (Yellow)
Interlock selection input (White)
+24V (Brown)
Communication
line (+) (Grey)
Communication
line (-) (Pink)
+24V (Brown)
External devace monitoring input (Red)
Auxiliary output 1 (Yellow)
Safety output 1 (Green)
Safety output 2 (White)
0V (Blue)
Shield
Unblocked
Blocked
External test switch
(S1)
Interlock reset switch
(S2)
Emergency stop switch
(S3)
Safety output1, 2
K1,K2 N.O. contact
KM1,KM2 N.O. contact
K1,K2 N.C. contact
KM1,KM2 N.C. contact
PLC input 1(*)
PLC input 2
PLC output
S1
:External test switch (connect to 0V if a switch is not required)
S2
:Interlock reset switch
S4
:Lockout reset switch (connect to 24V if a switch is not required)
KM1, KM2 :Magnetic contactor
KM3
:Solid state contactor (G3J)
M :3-phase
motor
E1
:24VDC power supply (S82K)
PLC :Programmable
controller
(Used for monitoring -- not related to safety system)
- F3SJ settings
- Auto reset mode
- Does not use external device monitoring function
- G9SB-301-D settings
- Manual reset mode
- Using feedback loop
*1 The G9SB-200-D (17.5 mm thick), with no 33-34 and 41-42, is also available.
S3
: Emergency stop switch (forcibly-opening contact)
(A165E, A22E)
*2 If an emergency stop switch is not used, connect safety output 1 to T12
terminal and safety output 2 to T22 directly.
S4
Auxiliary output 2 (Red)
* Output operation mode of auxiliary output 1 is "safety output information/reverse enabled" (initial setting)
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com