No.18S075-00
33/48
STC-OSB250CL
Product Specifications
and User’s Guide
Command No.
Command Description
50H:
FFC_BURST_MOD
E
[1..0]
[Obtains FFC data] Default: FFC_BURST_MODE[1..0] = 00H
Obtains FFC data.
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D2
No Function
Always sets as “000000”
D1
Select obtaining FFC Data
0: FFC Data with
Black image
1: FFC Data with
White image
D0
Obtains FFC Data
0: OFF
1: ON
*
Please refers “Obtains FFC Data” for more details.
51H:
FFC_MODE [7..0]
[FFC gain] Default: FFC_MODE[7..0] = 200, Data range: 0 to 255
Sets output gain for FFC function.
52H:
FFC_CLAC_EN [0]
[FFC mode] Default: FFC_CLAC_EN[0] = 0
Selects ON / OFF for FFC function.
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D1
No Function
Always sets as “0000000”
D0
FFC Function
0: FFC OFF
1: FFC ON
68H:
BACKEND_MODE_
L
[7..0]
[Flip image] Default data:
FLIP
[7..0] = 00H
Sets the image output direction.
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D6
No Function
Always sets as
“00”
D5
Image output direction
(Vertical)
0: Normal image
1: Vertical flipped image
D4
Image output direction
(Horizontal)
0: Normal image
1: Horizontal flipped image
D3 to D0
No Function
Always sets as
“0000”
78H:
TEST_PATTERN_S
EL
[2:0]
[Test Pattern] Default data: TEST_PATTERN_SEL[2..0] = 0, Data range: 0 to 7
Sets the output test pattern.
D7
D6
D5
D4
D3
D2
D1
D0
D7 to D3
No Function
Always sets as
“00000”
D2 to D0
Test Pattern
0: Off (Image output)
1: Gray scale image
2: Horizontal lamp image
3: Vertical lamp image
4: White image
5: Black and white grids image
6 to 7: Black image