6.2.6.3 Measured External Trigger Signal Delay through Opt-Isolated Port (Line 0)
Measurement circuit
Positive polarity trigger signal
Negative polarity trigger signal
Pull-up voltage
Tdelay
Minimum active
pulse duration
Pull-up voltage
Tdelay
Minimum active
pulse duration
+3.3 V
8.2 μseconds
6 μseconds
+3.3 V
47 μseconds
6 μseconds
+12 V
4.6 μseconds
3 μseconds
+12 V
53.2 μseconds
3 μseconds
+24 V
4.4 μseconds
2 μseconds
+24 V
53.2 μseconds
2 μseconds
Note. Please use this measured delay as reference. The delay time may fluctuate depending on photo coupler